CDSCO public Form MD-14 checklist — IVD — Public Form MD-14 IVD import checklist — fresh, endorsement and retention
Currentness under review. Whether this instrument remains applicable is under review. Consult the later instruments and source context below before relying on it.
Link directly to a passage with its anchor — for example #pdf-page-1 — to open it highlighted. This reference version is generated from the authority’s publication and does not replace it. Language: English.
Contents
CHECKLIST
Form Name: Form MD-14
Category: IVD
FRESH
Section no. Checklist Name Is Mandatory
1.0 Covering Letter, Yes
Power of Attorney (Original) authenticated
2.0 in India either by a Magistrate of First Class Yes
or by Indian Embassy in the country of
origin or by an equivalent authority
through apostille along with under taking
from the authorized agent as specified in
Part I of Forth Schedule,
Self attested copy of valid Whole sale licence
3.0 Yes
or manufacturing licence if any,
Regulatory Certificates along with previous
4.0 No
import license.(if any)
Notarized copy of overseas manufacturing
4.1 site or establishment or plant registration, by Yes
whatever name called, in the country of
origin issued by the competent authority,
Notarized and valid copy of Free Sale
4.2 Certificate issued by the National Regulatory Yes
Authority or equivalent competent authority
of the country of origin.(if any)
Notarized and valid copy of Free Sale
4.3 Certificate issued by the National Regulatory Yes
Authority or equivalent competent authority
of the any of the countries namely United
States of America, Australia, Canada, Japan,
and European Union Countries.
copy of latest inspection or audit report
4.4 carried out by Notified bodies or National Yes
Regulatory Authority or Competent
Authority within last 3 years, if any.
copy of NOC from Department of Animal
4.5 Husbandry, Ministry of Agriculture, In Case Yes
of Veterinary IVD Kits,
copy of NOC from Bhabha Atomic Research
4.6 Centre (BARC), Mumbai, In case Radio Yes
Immuno Assay Kits,
Quality Management System certificate in
5.0 respect of legal and actual manufacturing No
sites(s) (Wherever applicable),
Notarized and valid copy of Quality
5.1 Management System certificate (ISO 13485) Yes
certificate issued by the competent
authority,
Notarized and valid copy of Production
5.2 Quality Assurance certificate or Full quality Yes
Assurance certificate issued by the
competent authority.(if any)
CDSCO public Form MD-14 checklist — IVD — official PDF page 1
Notarized and valid copy of CE design
5.3 certificate issued by the competent Yes
authority.(if any),
Site or plant master file as specified in
6.0 No
Appendix I of Fourth Schedule of MDR 2017.,
6.1 Part 1, Yes
6.2 Part 2, Yes
6.3 Part 3, Yes
6.4 Part 4, Yes
Device Master File for In Vitro Diagnostic
7.0 Medical Devices as per Appendix – III of Part No
III of Fourth Schedule of Medical devices
Rules, 2017
Part-1 Executive Summary, Description and
7.1 specification, including variants and Yes
accessories and Design & manufacturing
information of the in vitro diagnostic medical
device
Part-2 Regulatory status of the similar device
7.2 in India (approved or new in vitro diagnostic Yes
medical device).
7.3 Part – 3 Essential principles checklist Yes
Part – 4 Risk analysis and control summary,
7.4 Product validation and verification and Yes
Clinical Evidences
Part-5 Analytical studies, Specimen type,
7.5 Analytical performance characteristics, Yes
Analytical sensitivity, Analytical Specificity,
Metrological traceability of calibrator and
control material values, Measuring range of
assay, Definition of assay
Part – 6 Claimed Shelf life – stability study
7.6 report for at least 3 lots including the Yes
protocol, acceptance criteria, testing
intervals and conclusion, In use stability
study report for 1 lot including the protocol,
acceptance criteria, testing intervals and
conclusion & Shipping stability study report
for 1 lot including the protocol, acceptance
criteria, testing intervals and conclusion.
7.7 Part-7 Product Insert, Pack size, Label Yes
Part-8 Specimen batch test report for at least
7.8 consecutive 3 batches showing specification Yes
of each testing parameter
CDSCO public Form MD-14 checklist — IVD — official PDF page 2
Part-9 Copy of performance evaluation
7.9 report issued by the central medical device Yes
testing laboratory or medical device testing
laboratory registered under sub-rule (3) of
rule 83 of MDR 2017 for three batches/
Specific evaluation report, if done by any
laboratory in India, showing the sensitivity
and specificity of the in-vitro diagnostic
medical device
Part-10 Post Market Surveillance Data and
7.10 Yes
any other information of the product
Correlation chart with respect to products
8.0 Yes
list mentioned in MD-14 and FSC submitted,
Testing method preferably in Video (if
9.0 Yes
available),
10.0 Fee Chalan Yes
11.0 Legal Form Yes
ENDORSEMENT
Mandatory or
Section no. Checklist Name
NO RECORD FOUND not
1.0 Covering Letter, Yes
Power of Attorney (Original) authenticated in
2.0 India either by a Magistrate of First Class or Yes
by Indian Embassy in the country of origin
or by an equivalent authority through
apostille along with under taking from the
authorized agent as specified in Part I of
Forth Schedule,
Self attested copy of valid Whole sale licence
3.0 Yes
or manufacturing licence if any,
Regulatory Certificates along with previous
4.0 No
import license.
Notarized and valid copy of Free Sale
4.1 Certificate issued by the National Regulatory Yes
Authority or equivalent competent authority
of the country of orgin.(if any)
Notarized and valid copy of Free Sale
4.2 Certificate issued by the National Regulatory Yes
Authority or equivalent competent authority
of the any of the countries namely United
States of America, Australia, Canada, Japan,
and European Union Countries.
copy of latest inspection or audit report
4.3 carried out by Notified bodies or National Yes
Regulatory Authority or Competent Authority
within last 3 years, if any.
copy of NOC from Department of Animal
4.4 Husbandry, Ministry of Agriculture, In Case of Yes
Veterinary IVD Kits,
copy of NOC from Bhabha Atomic Research
4.5 Centre (BARC), Mumbai, In case Radio Yes
Immuno Assay Kits,
CDSCO public Form MD-14 checklist — IVD — official PDF page 3
Quality Management System certificate in
5.0 respect of legal and actual manufacturing No
sites(s) (Wherever applicable),
Notarized and valid copy of Quality
5.1 Management System certificate (ISO 13485) Yes
certificate issued by the competent authority,
Notarized and valid copy of Production
5.2 Quality Assurance certificate or Full quality Yes
Assurance certificate issued by the
competent authority.(if any)
Notarized and valid copy of CE design
5.3 certificate issued by the competent authority. Yes
(if any),
Device Master File for In Vitro Diagnostic
6.0 Medical Devices as per Appendix – III of Part No
III of Fourth Schedule of Medical devices
Rules, 2017
Part-1 Executive Summary, Description and
6.1 specification, including variants and Yes
accessories and Design & manufacturing
information of the in vitro diagnostic medical
device
Part-2 Regulatory status of the similar device
6.2 in India (approved or new in vitro diagnostic Yes
medical device).
6.3 Part – 3 Essential principles checklist Yes
Part-4 Risk analysis and control summary,
6.4 Product validation and verification and Yes
Clinical Evidences
Part-6 Claimed Shelf life – stability study
6.5 report for at least 3 lots including the Yes
protocol, acceptance criteria, testing intervals
and conclusion, In use stability study report
for 1 lot including the protocol, acceptance
criteria, testing intervals and conclusion &
Shipping stability study report for 1 lot
including the protocol, acceptance criteria,
testing intervals and conclusion.
Part-5 Analytical studies, Specimen type,
6.6 Analytical performance characteristics, Yes
Analytical sensitivity, Analytical Specificity,
Metrological traceability of calibrator and
control material values, Measuring range of
assay, Definition of assay
6.7 Part-7 Product Insert, Pack size, Label Yes
Part-8 Specimen batch test report for at least
6.8 consecutive 3 batches showing specification Yes
of each testing parameter
Part-9 Copy of performance evaluation
6.9 report issued by the central medical device Yes
testing laboratory or medical device testing
laboratory registered under sub-rule (3) of
rule 83 of MDR 2017 for three batches/
Specific evaluation report, if done by any
laboratory in India, showing the sensitivity
and specificity of the in-vitro diagnostic
medical device
Part-10 Post Market Surveillance Data and
6.10 Yes
any other information of the product
Correlation chart with respect to products list
7.0 Yes
mentioned in MD-14 and FSC submitted,
Testing method preferably in Video (if
8.0 Yes
available),
CDSCO public Form MD-14 checklist — IVD — official PDF page 4
9.0 Fee Chalan Yes
10.0 Legal Form Yes
RETENTION
Mandatory or
Section no. Checklist Name
not
Copy of the license and its covering letter,
1.0 along with a copy of post approval changes to Yes
the license (if any), and the wholesale/
manufacturing license of the authorized agent
Copy of license and its covering letter, along
2.0 with a copy of Conditional fulfillment (if any), Yes
and product/license surrender copy (if any)
Valid Free Sale Certificate/Marketing
3.0 Authorization of the product from National Yes
Regulatory Authority of country of origin (if
any) and Free Sale Certificate/Marketing
Authorization of the product from National
Regulatory Authority of any of the following
countries viz USA, EU, UK, Canada, Japan,
Australia.
Copy of Certificate supporting Quality
4.0 Management System, Full Quality Assurance Yes
Certificate/ CE type examination Certificate/
CE product quality assurance certificate, CE
design Certificate, DOC etc.,
An undertaking from the manufacturer
5.0 stating that there is no change(s) in the Yes
existing Device Master File (DMF), Plant
Master File (PMF) and Constitution of the firm
Post marketing surveillance data (Vigilance
6.0 reporting) during last 5 yrs. (details of Yes
complaints, recall from any country (if any),
CAPA taken, etc), duly authenticated by the
manufacturer or authorized agent.
Undertaking duly signed and stamped by the
7.0 manufacturer and authorized Indian agent Yes
stating that there is no change in the Power of
Attorney (POA). In case any change in a copy
of fresh Power of Attorney (Original) as
specified in Part I of Forth Schedule may be
submitted.
8.0 Duly Signed Retention Form Yes
9.0 Bharat kosh receipt Yes
CDSCO public Form MD-14 checklist — IVD — official PDF page 5