Spinal Implant is a medical device registered with India's Central Drugs Standard Control Organization (CDSCO) under UID MFG/MD/2020/000080_824a29e2188d836c1ea153f79c0c894b_50b83b5c0ca7953459428dd8b4f87b55. The license holder is GREENS SURGICALS (P) LTD., and it is classified as Device Class Class C. The approving authority is Central Drug Standards Control Organization, Ahmedabad.

This page provides comprehensive regulatory information including complete registration details, license holder information, device classification, and related products. Pure Global AI offers free access to 71,807+ India medical device registrations, helping global MedTech companies identify partners, analyze markets, and discover business opportunities efficiently.

Free Database
Powered by Pure Global AI
CDSCO Registered
Class Class C
Spinal Implant
UID: MFG/MD/2020/000080_824a29e2188d836c1ea153f79c0c894b_50b83b5c0ca7953459428dd8b4f87b55

Device Class

Class C

Approving Authority

Central Drug Standards Control Organization, Ahmedabad

Product Information

Titanium alloy ##PLACEHOLDER_0## Grade 5##PLACEHOLDER_0##-:Anterior Cervical Plate and Screw: The Anterior Cervical Plate System is indicated for stabilization of the cervical spine from C2 to C7 employing screw fixation at the anterior face of the vertebral bodies. Specific clinical indications for anterior plating include: instability caused by trauma; instability associated with correction of cervical lordosis and kyphosis deformity; instability associated with pseudoarthosis as a result of previously failed cervical spine surgery; instability associated with single or multiple level corpectomy in advanced degenerative disc disease, spinal canal stenosis and cervical myelopathy Monoaxial Screws and Hooks with spinal rods: The monoaxial screws and hook system are intended for use a posterior pedicle screw fixation system ##PLACEHOLDER_0## or posterior hook fixation system ##PLACEHOLDER_0## or as an anterolateral fixation system ##PLACEHOLDER_0##. These devices are intended for all the below: Degenerative Disc Disease, Spondylolisthesis, trauma, deformities or curvatures, stenosis, pseudoarthrosis and failed previous fusion. Polyaxial Screws with Spinal Rods: The polyaxial screw and rod system are intended for providing segmental stabilization of the spine in skeletally mature patients. Drummerโ€™s wire Intended Use / Application: These wires are generally used in spine fractures along with Hart Shells. Hart shell Intended Use / Application: Hart Shall are generally used in spine fractures along with Drummerโ€™s Wires. Harrington rod & hooks Intended Use / Application: Harrington Rods are used in spinal surgery. Harrington Rod is used along with Harrington Hooks in spinal fractures

Pure Global
DJ Fang

DJ Fang

MedTech Regulatory Expert

Need help with 30+ markets registration?

Pricing