Design Validation is 의료기기가 실제 또는 시뮬레이션된 사용 조건에서 사용자 요구사항과 의도된 용도를 충족함을 확인하는 테스트 및 증거입니다.
Complete Guide to Design Validation
Design Validation is a critical element of FDA Design Controls (21 CFR 820.30) that confirms a medical device meets user needs and intended uses under actual or simulated use conditions. It answers the question: "Did we build the right thing?"
Design Validation vs Design Verification:
- Validation - Building the RIGHT thing (meets user needs)
- Verification - Building it right (meets design specifications)
Key aspects of Design Validation:
What must be validated:
- Device performs as intended in actual use environment
- Device meets user needs identified in design inputs
- Device is safe and effective for intended users
- Labeling and instructions are adequate
- Device can be used by intended user population
Validation methods:
- Clinical validation - Testing with actual patients in clinical settings
- Simulated use testing - Testing with representative users in controlled environment
- Human factors validation - Usability testing with intended users
- Performance validation - Testing under actual use conditions
- Shelf life validation - Confirming stability over product lifetime
Timing of validation:
- Must occur before design transfer to manufacturing
- Performed on production-equivalent units
- May require multiple validation studies
Documentation requirements:
- Validation protocol (objectives, methods, acceptance criteria)
- Test results and data analysis
- Conclusion that device meets user needs
- Documented in Design History File (DHF)
Regulatory requirements:
- FDA 21 CFR 820.30(g) - Design Validation
- ISO 13485:2016 Section 7.3.6 - Design and Development Validation
- EU MDR - Clinical Evaluation and Performance Testing
When validation must be repeated:
- Design changes affecting safety or effectiveness
- Changes to intended use or user population
- Manufacturing process changes
- New or modified clinical indications
A successful validation demonstrates that your device meets real-world user needs, not just engineering specifications.
Related Terms
More Compliance & Standards
View all미국 의료기기 제조업체에 대한 현행 우수 제조 관리 기준(cGMP) 요구사항을 규정하는 FDA의 품질 시스템 규정(QSR).
품질 활동 및 결과가 계획된 약정을 준수하는지 여부와 이러한 약정이 효과적으로 구현되고 있는지 확인하기 위한 품질 관리 시스템의 체계적이고 독립적인 검사.
의료기기 제조 및 운영에서 품질 문제를 조사, 시정 및 예방하기 위한 체계적인 접근 방식.
유럽경제지역에서 판매되는 의료기기에 필수인 적합성 표시로, EU 보건, 안전 및 환경 요건 준수를 나타냄.
Need Help with Global Registration?
Pure Global provides regulatory consulting and AI-powered tools to help medical device companies navigate Global market access.