PMS (Post-Market Surveillance) is 시장에 출시된 후 의료기기의 성능과 안전성에 대한 데이터를 수집하고 분석하기 위한 사전 예방적이고 체계적인 프로세스.
Complete Guide to PMS
Post-Market Surveillance (PMS) is a mandatory regulatory requirement under EU MDR Articles 83-86 that requires manufacturers to establish and maintain a systematic, proactive process for collecting, recording, and analyzing data about the quality, performance, and safety of medical devices throughout their lifecycle after market placement.
EU MDR requirements:
Under the EU Medical Device Regulation (EU) 2017/745, every manufacturer must:
- Establish a post-market surveillance system appropriate to the risk class and device type
- Develop and maintain a documented PMS plan
- Generate periodic PMS reports (or Periodic Safety Update Reports for higher-risk devices)
- Actively collect and analyze data from multiple sources
PMS plan requirements:
The PMS plan must include:
1. General information - Device identification, classification, risk class
2. Data collection methods - Sources and procedures for gathering data
3. Data analysis methods - Statistical techniques and trend analysis approaches
4. Objectives - Specific safety and performance metrics to monitor
5. Timelines - Frequency of data collection, analysis, and reporting
6. Responsibilities - Roles and responsibilities for PMS activities
7. Vigilance link - Connection to complaint handling and vigilance reporting
Data sources for PMS:
Manufacturers must collect information from:
- Customer feedback - Complaints, returns, service reports
- Clinical data - Post-market clinical follow-up (PMCF) studies
- Literature - Scientific publications and clinical evidence
- Market data - Sales volumes, installation base, usage patterns
- Competent authority reports - Safety communications, field safety notices
- Similar devices - Incidents and safety data from comparable products
- Social media and forums - User experiences and discussions
PMS report requirements:
The PMS report must summarize:
- Data collected during the reporting period
- Evaluation of data and trend analysis
- Number and types of incidents
- Risk-benefit analysis updates
- Volume of sales and estimated population exposed
- Summary of corrective actions taken
- Conclusions and proposed preventive actions
Reporting frequency by risk class:
- Class I - Part of technical documentation, updated as needed
- Class IIa - PMS report updated when technical documentation updated
- Class IIb - PMS report at least every 2 years
- Class III/Implantable - Periodic Safety Update Report (PSUR) annually
Relationship to other post-market activities:
PMS is closely integrated with:
- Vigilance - Mandatory reporting of serious incidents and field safety corrective actions
- PMCF - Clinical follow-up studies to gather clinical safety and performance data
- Trend reporting - Identification of statistically significant increases in incidents
- Risk management - Ongoing evaluation and update of risk analysis
PMS vs PMCF:
| Aspect | PMS | PMCF |
|--------|-----|------|
| Scope | All quality, safety, performance data | Clinical data specifically |
| Methods | Complaints, literature, market data | Clinical studies, registries, surveys |
| Requirement | All devices | Focus on higher-risk devices |
| Output | PMS report or PSUR | PMCF evaluation report |
Compliance considerations:
- PMS is a proactive requirement, not reactive - manufacturers cannot wait for problems
- Insufficient PMS is a leading cause of notified body audit findings
- PMS must be tailored to device risk and specific safety concerns
- Data must be analyzed, not just collected
- PMS plan must be reviewed and updated regularly
PMS is a cornerstone of the EU MDR's lifecycle approach to medical device safety, ensuring that real-world experience continuously informs the risk-benefit evaluation of marketed devices.
Related Terms
More Clinical & Post-Market
View all의료기기 사용과 관련된 바람직하지 않은 경험으로, 환자 위해, 상해, 오작동 또는 아차사고를 포함하며 규제 당국에 보고해야 함.
의료기기의 임상적 이점을 위험과 비교하여 의도된 용도에 대한 수용 가능성을 결정하는 체계적 평가.
EU MDR에 따라 의료기기의 안전성과 성능을 입증하기 위해 임상 데이터를 평가하고 문서화하는 필수 종합 문서.
의료기기의 안전성과 성능을 평가하기 위해 인간 피험자를 대상으로 수행되는 체계적인 연구. EU 규정에 따라 특정 기기의 CE 마킹 전에 필요.
Need Help with EU Registration?
Pure Global provides regulatory consulting and AI-powered tools to help medical device companies navigate EU market access.