Research Department of Drugs and Food registration records, classification, regulations, timelines, fees, and market updates — the stable entrance to every Cambodia medical device resource.
Describe your device and get a preliminary DDF risk class with an explanation and source links.
Check whether product features may trigger separate radio, electrical, metrology, radiation, import, or other Cambodia requirements.
Compare official and realistic approval times by device class and pathway.
Browse Cambodia's official medical-device instrument — the ASEAN Medical Device Directive as published by the ASEAN Secretariat — with citeable English passages.
Common questions about changing a registered medical device in Cambodia. Each question separates published rules from details still awaiting verification.
22 of 25 research dimensions currently covered · 14 official sources · latest verification 2026-09-17
No source-verified answer is published for this dimension yet.
Department of Drugs and Food, Ministry of Health (Department of Drugs and Food) review clocks and planning ranges · 4-class (A, B, C, D) — ASEAN Medical Device Directive; class A is recorded as low risk and class D as high risk in Article 4(1) classification
| Class / pathway | Review clock | Planning total | Provenance |
|---|---|---|---|
| TRC qualified-agent certificate — importer, supplier and distributor of radiocommunication, telecommunication and ICT equipment(Application to the Telecommunication Regulator of Cambodia through its online portal by a firm registered in Cambodia; the certificate is a precondition for a type approval and for a restricted-goods import permit (Law on Telecommunications Article 16(a); Sub-Decree No. 110 ANK/BK Article 7(a))) Cambodia's notification states the certificate 'shall be approved within 15 business days by TRC' for an eligible application; the 15 is recorded in the registry's working-days unit, which is the basis the instrument itself uses. The certificate is valid for two years and may be renewed 30 days before expiry; it is not transferable. Only a firm registered in Cambodia can hold it, and only a holder can obtain a type approval or an import permit — this is the importer-side clock, not the device clock. | 15 working days | 3-6 weeks | Verified |
| TRC type-approval certificate — per equipment model(Application to the TRC on the Prakas No. 208 basis, filed by a qualified agent and enclosing EMC, safety and RF test reports; the certificate is issued for each imported model and must exist before the equipment is imported (Law on Telecommunications Article 16(b); Sub-Decree No. 110 ANK/BK Article 7(b))) The notification states the type-approval certificate 'shall be approved within 15 business days'. The application route is still processed manually and the TRC states it will move the service to its online portal. The notification records the validity as permanent — a lifetime validity for the model, recorded here as the instrument's own wording rather than as a renewal cycle. Applies to a medical device only where the device is radiocommunication, telecommunication or ICT equipment; a device without that feature does not take this clock. Prakas No. 499 of 8 May 2018 sets the type-approval tariff at an 80,000 riel application fee and a 4,000,000, 6,000,000 or 8,000,000 riel certificate fee by service line — a radio-equipment charge, so it is not published in the Cambodian fee dataset. | 15 working days | 3-8 weeks | Verified |
| TRC import permit — restricted radiocommunication and ICT goods(Application through the National Single Window for goods in Annex 2 of Sub-Decree No. 370 ANK/BK of 28 December 2023, filed by a qualified agent and supported by an existing type approval for the model) The notification states the permit 'shall generally be approved by TRC within 3 business days through the National Single Window online system', and that it is granted within 3 business days where the goods already hold a type approval and the documents are complete. One permit covers one shipment and the permit is not transferable. The permit is keyed to the HS headings listed in Annex 2 of Sub-Decree No. 370, which are networking, transmission, camera, drone and parts headings; a medical device is caught only where its heading is on that list. | 3 working days | 1-3 weeks | Verified |
| Class A, B, C and D — Department of Drugs and Food medical-equipment visa registration (វិញ្ញាបនបត្រទិដ្ឋាការ បញ្ជីការ សម្ភារៈ បរិក្ខារពេទ្យ)(Dossier filed with the Department of Drugs, Food, Medical Equipment and Cosmetics through the One Window Service Office of the Ministry of Health, on the attachment list the service schedule publishes (GMP/ISO certificate, Free Sale certificate, sterility and Certificate-of-Analysis documents) and the ASEAN Common Submission Dossier Template route of AMDD Article 8(a); registration is per medical-equipment product and the certificate is valid three years) MANDATORY CAVEAT — THIS IS A 2016 AUTHORITY-PUBLISHED SERVICE STANDARD, NOT AN ARTICLE OF THE IN-FORCE PRAKAS. The Ministry of Health's Public Service Information (2016 update) populates the 'រយៈពេលផ្តល់ជូន' (period provided) field for this service with 3-4 months and decomposes it into four one-month stages — examination of the documents and return to the company; preparation of the visa sub-committee meeting; preparation of the deciding committee meeting; and issue of the certificate once the committee has agreed. Four one-month stages are exactly the upper bound of the range. The device visa-registration procedure was re-promulgated by the Department of Drugs and Food in 2025, and that prakas is published only as a four-page image-only scan with no text layer, so it could not be read and could not be checked against this figure. If it restates, changes or drops the standard, its text governs; nothing here should be read as the statutory maximum. This replaces the row's earlier verified negative: no retrievable Cambodian instrument states a decision period is still true of the ASEAN Medical Device Directive (Article 6 obliges a registration system and states no period) and of the National Trade Repository page for this procedure, but the Ministry's own consolidated schedule does state one, as a service standard. The schedule's Khmer is set partly in legacy-mapped fonts, so extraction interleaves correct Unicode with substituted glyphs; everything published here rests on the Khmer and Arabic digits, which survive the substitution, and on a service identity confirmed by three independent match points against the official National Trade Repository page for the same procedure — the 400,000 riel fee, the three-year validity and the renewal at 70% of the original price. The most consequential silence in this route is that neither official description states a deadline for the applicant to return a corrected file, which is what makes the published 3-4 months unenforceable in practice. Registration is per device; no Cambodian instrument retrieved permits grouping several devices under one registration. The row is route-wide rather than class-specific because the schedule fixes one period for the service across classes A to D, which is why it carries a risk-class-link exemption rather than a class link. | 3-4 months | 3-8 months | Verified |
Official Department of Drugs and Food rules and guidance · 1 of 1 documents linked to official sources
The target market is carried into each tool. Add the product, evidence, or regulatory change you want to assess.
Structure company, product, model, approval, certificate, and evidence facts before starting Cambodia work.
Connect the Department of Drugs and Food route, evidence, labels, local role, timing, and dependencies to a wider launch plan.
Compare an existing authorization and evidence set against Department of Drugs and Food administrative, testing, labeling, and dossier needs.
Map a product or manufacturing change to Department of Drugs and Food evidence, notification, timing, and implementation questions.
Assess a current Department of Drugs and Food update against one product and turn it into an owner-ready action workpaper.
Review connected-device architecture, risks, SBOM, testing, lifecycle controls, and market-specific questions for Cambodia (Department of Drugs and Food).