State Medicines Control Agency under the Ministry of Health (VVKT) review clocks and end-to-end planning ranges, using the 4-class (I, IIa, IIb, III) — EU MDR classification system.

1 pathways1 of 1 clocks verifiedvalidity 5 years (CE certificate)MDSAP not acceptedreviewed 2026-08-25
Class / pathwayReview clockPlanning totalWith prior approvalProvenance
Class I(Self-certification (MDR) with national registration entry)
National register entry published within 20 working days of a complete application (HSL iš Lietuvos Respublikos sveikatos apsaugos ministro įsakymas); EU MDR self-certification runs in parallel
20 working days1-2 monthsVerified
Review clocks exclude applicant hold time · planning totals are estimates

Lithuania Medical Device Registration Process

Step-by-step VVKT registration process. Total estimated timeline: 1-2 months.

Step 1: Pre-Submission Preparation

1-3 months

Gather technical documentation, quality management system (QMS) records, and clinical data required by VVKT. Appoint a EU Authorized Representative.

Step 2: Application Submission

1-2 weeks

Submit complete registration dossier to VVKT including device description, risk analysis, and testing reports.

Step 3: Administrative Review

2-4 weeks

VVKT reviews application for completeness. May request additional documents or clarifications.

Step 4: Technical Evaluation

20 working days

In-depth technical assessment of device safety and performance. VVKT may issue questions.

Step 5: Registration Approval

1-2 weeks

Upon successful review, VVKT issues Lithuania market authorization certificate.

Summary: The Lithuania medical device registration process through State Medicines Control Agency under the Ministry of Health (VVKT) consists of 5 main steps: Pre-Submission Preparation → Application Submission → Administrative Review → Technical Evaluation → Registration Approval.
Prior approval recognition
FDA 510(k)/PMANo substitute for EU MDR conformity assessment; useful as predicate documentation in the technical file
Key requirements
  • EU Authorized Representative (for non-EU manufacturers)
  • National Class I/IVD registration: register entry published within 20 working days; deficiencies must be cured within 30 days
  • Class IIa/IIb/III distributors/manufacturers established in Lithuania notify VVKT within 14 working days
  • Free-sale certificate issued within 20 working days