Azerbaijan medical device regulations

Official sources linked

Ministry of Health rules and guidance for medical device market access, registration, and lifecycle compliance. Each code opens a metadata page with the official source and readable HTML when available.

1 documents1 categories100% linked to official sourcesauthority Ministry of Health1 readable HTML
CodeRegulationCategoryEffectiveProvenance
Cabinet Decision No. 345 of 18 July 2024
Rules for State Registration, Entry in the State Register and Keeping of the State Register of Medicines, Pharmaceutical Substances and Medical Devices
Azərbaycan Respublikası Nazirlər Kabinetinin 2024-cü il 18 iyul tarixli 345 nömrəli Qərarı, signed in Baku on 18 July 2024. Its first three items approve the Rules for state registration, entry in the state register and keeping of the state register of medicines, pharmaceutical substances and medical devices (the Rules are annexed to the decision); repeal Cabinet Decision No. 108 of 13 July 2007 on the same ground; and provide that amendments to the decision may be made under §3.5 of the Regulation approved by Presidential Decree No. 2328 of 6 October 2023. The Rules run to 13 sections (§1 general provisions, §2 concepts, §3 registration of medicines and substances, §4 registration and re-registration of medical devices and changes to their registration documents, §5 grounds of refusal, §6 certificates for medicines and substances, §7 certificates for medical devices, §8 validity, §9 approval of instructions for use, §10 the state register, §11 suspension, §12 cancellation, §13 confidentiality) and nine appendices. Device-specific content: only devices of higher-than-high, high and/or medium risk are state-registered at all (§1.2.3, §4.2); the applicant files the documents of §4.2.1–4.2.11, several of which are excused for devices manufactured in Azerbaijan and for in-vitro diagnostic devices (§4.3); the Ministry issues the certificate within 7 working days on the form of Appendix No. 5 (§7.1), and a new certificate for changes to its particulars on the form of Appendix No. 6 (§7.2); the certificate is valid for 5 years (§8.1); the state register records the device's risk degree (§10.4.3). Appendices Nos. 5 and 6 are the medical-device certificate forms (headed "TV №"); Appendices Nos. 2A–4B are the medicinal-product and substance certificate forms ("DV №"); Appendix No. 1 is the application form. Ingested in Azerbaijani from the Cabinet of Ministers' own PDF.
Registration—Official
Exports carry source + retrieval date

Changes after registration in Azerbaijan

Source-linked rules for common changes to a registered medical device. Read the scope and conditions with each rule; unverified details are listed separately.

Does changing a device brand name or logo require an update?

A change to the registered brand name and a change to logo artwork can follow different rules. The legal manufacturer, device design and intended purpose remain the same.

A source-verified answer for this specific scenario is not yet published.

How do I update a manufacturer's name without changing the legal entity?

The same legal manufacturer changes its name, potentially alongside the device brand. A transfer to another legal entity is a separate question; permission to combine filings needs its own evidence.

A source-verified answer for this specific scenario is not yet published.

What changes when the manufacturer's office address changes?

An office address change for the same legal entity, potentially alongside name and brand changes. This does not cover moving a factory or manufacturing site, and a combined filing cannot be assumed.

A source-verified answer for this specific scenario is not yet published.

Does a catalogue or reference code change affect registration or UDI?

Check which identifier actually changes. A commercial catalogue, REF or order code is not automatically a device model, registered identifier, GTIN or UDI-DI. Rules for one identifier do not establish the route for another.

A source-verified answer for this specific scenario is not yet published.

Can several changes be filed together?

Changes to brand, manufacturer name, office address and reference codes may occur together, including with a real transfer to another legal manufacturer, registration holder or owner. Assess transfer with each single change, and transfer with brand plus reference, manufacturer name plus reference, or office address plus reference changes: seven transfer combinations in total. Evidence must establish the exact combination and the order of filings and approvals. These combinations and their sequence are not all verified by the rules below; a rule for one change does not prove that a single application, fee or review period covers the combination.

A source-verified answer for this specific scenario is not yet published.

Regulation codes

What these codes are

Each row above represents one regulatory instrument. Its code is the authority’s identifier. A regulation page collects the metadata and official source; when readable HTML is available, article links can open and highlight the exact cited passage.

Use this market context

Continue from regulations into practical research

Keep Azerbaijan as the target market while you move into registration records, classification, cross-country product research, or pathway planning.

Keep researching this market
View the Azerbaijan resource hub →
Compare regulations across all countries →