14 documents3 categories100% linked to official sourcesauthority Ministry of Health10 readable HTML
CodeRegulationCategoryEffectiveProvenance
Quyết định 3618/QĐ-BYT
Decision 3618/QĐ-BYT — medical-device administrative procedures under Circular44/2025, 24 November 2025
Complete 324-page official publication of14 medical-device administrative procedures, preserving all forms, registration branches and ancillary procedures. Relevant C/D continued-circulation procedure6 is physical259–262; C/D CFS procedure7 is263–266. Registration procedures1–5 include bounded prior-registration/name/owner/code conditions. These are not a universal rename or holder-transfer route. The printed fee wording is historical and does not certify a current tariff. Original page images are authoritative; native PDF text is only a qualified search layer and may contain overlay/extraction artifacts. Legal currentness is unverified.
Registration2025-11-24Official
Quyết định 2075/QĐ-BYT
Decision 2075/QĐ-BYT — medical-device administrative procedures, 24 June 2025
Complete 25-page historical publication, including central C/D and provincial A/B continued-circulation and CFS procedures with forms, and the IVD-related controlled-precursor declaration. Decision3618/2025 Article2 later preserves only the two corresponding A/B procedures from this expression. This complete old expression must not be treated as all current procedures or a current fee schedule. Original page images are authoritative; native PDF text is only a qualified search layer and may contain overlay/extraction artifacts. Legal currentness is unverified.
Registration2025-07-01Official
Thông tư 44/2025/TT-BYT
Circular 44/2025/TT-BYT — delegation, forms and reports for medical devices
Complete 105-page official circular dated 22 November 2025 with its annexes. Article 4 states commencement on that date, while Article 5 preserves specified transition conditions for existing dossiers, authorizations and warranty documents. The text delegates specified Ministry of Health procedures and supplies forms and reports; it does not itself establish a universal change procedure. Native search text contains interleaved diagonal digital-signature watermark fragments; original page images govern quotation and layout. Source preservation does not certify blanket current legal effect or whole-country completeness.
Registration—Official
59/2023/TT-BTC
Quy định mức thu, chế độ thu, nộp, quản lý và sử dụng phí trong lĩnh vực y tế
Complete seven-page signed official original of Circular59/2023/TT-BTC and its health-sector fee schedule. Medical-device/IVD transactions must be identified in the actual applicable entries; other health/drug matters remain complete source context. Temporary reductions and later instruments are separate conditions. No printed base rate is asserted as a perpetual current rate, generic variation fee, or whole-question answer.
Registration—Official
64/2025/TT-BTC
Quy định mức thu, miễn một số khoản phí, lệ phí nhằm hỗ trợ cho doanh nghiệp, người dân
Complete fifteen-page signed official expression of Circular64/2025/TT-BTC. All original pages and the qualified native PDF text are retained. The circular covers multiple sectors; only the actual health-fee branch and its referenced underlying instruments are potentially relevant to medical devices/IVDs. Its stated temporary periods and return-to-underlying-instrument conditions must be read with actual amendments. This source-only admission does not recalculate current fees, assume every fee is halved, promote facts or certify present-day legal currentness.
Registration—Official
579/TB-HTTB
Thông báo thực hiện nộp phí đúng quy định tại Thông tư số 64/2025/TT-BTC ngày 30/6/2025 của Bộ Tài chính
Complete one-page official fee-compliance notice referring to Circular64/2025/TT-BTC and underlying fee rules. The printed instrument number/date, fee-compliance conditions and scope are retained in the original image; any blanks or non-body digital native text remain unchanged. No broad fee update, legal-currentness claim, new fact or question-answer promotion is made.
Registration—Official
645/TB-HTTB
Thông báo về thay đổi mức thu các khoản phí lĩnh vực thiết bị y tế
Complete two-page official notice concerning changes in collection of medical-device fees. The original notice and all actual table entries/conditions remain authoritative; complete source images are mandatory where native PDF text is empty. This source-only expression is retained alongside the Ministry of Finance instruments and does not independently establish all current fees, a new variation classification or a question-completion status.
Registration—Official
Exports carry source + retrieval date

Changes after registration in Vietnam

Source-linked rules for common changes to a registered IVD. Read the scope and conditions with each rule; unverified details are listed separately.

Does changing a device brand name or logo require an update?

A change to the registered brand name and a change to logo artwork can follow different rules. The legal manufacturer, device design and intended purpose remain the same.

  • Filing route and prior approval
  • Change-specific review time

Class A/B updates and fresh-declaration triggers

Fact-level verified

For Class A/B devices and IVDs, Article28(4) lists name/address updates for the product owner or circulation-number holder and manufacturer name/address information, plus qualifying label/IFU changes. Notify with related documents and update the public dossier within five working days after the change. A new product owner, device kind/type/purpose, added manufacturing site or added product code instead triggers a fresh declaration under 28(3).

Conditions
  • Label/IFU route requires unchanged intended purpose and indications.
  • A commercial brand is not automatically a new device type or product owner.
  • Filing route and prior approval
  • Change-specific review time

Class C/D updates and new-registration triggers

Fact-level verified

For Class C/D devices and IVDs, Article 32(7) lists owner/holder name and address, manufacturer name/address, packaging, warranty and qualifying label/IFU updates. Notify with related documents and update the public dossier within ten working days. Article29(1)(b) requires a new circulation number for the listed substantive changes, including a new product owner or added product code, and changes outside32(7).

Conditions
  • Label/IFU updates require unchanged purpose, indications, functionality and performance.
  • Ten working days is the holder notification deadline, not an authority approval SLA.
  • Filing route and prior approval
  • Supporting documents

Current update forms and supporting evidence

Fact-level verified

Circular44/2025 Form 13(A/B) and Form 14(C/D) identify the existing number and show previously declared/issued information beside updated information, with related documents and a signed/stamped or digital-signature commitment. Update all affected dossier evidence consistently; these forms are not a transfer approval or a replacement for a new application when Article28(3) or29(1)(b) is triggered.

  • Labels and identifiers

REF mapping and an actual registered code change

Fact-level verified

First map a commercial order REF to the declared or registered product code/type and label. An added product code triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); A/B reductions are specifically listed under 28(4)(g). Article 32a permits a priority request where the old code was discontinued and the prescribed device-type facts remain unchanged. Its ten-working-day decision is priority acceptance, not final registration approval.

  • Existing stock and transition

Existing stock after a qualifying label notice

Fact-level verified

Articles28(4)(e) and32(7)(e) permit devices manufactured before the holder gives the qualifying label-change notice to continue circulating with the information declared/registered and updated at manufacture. A/B must keep intended purpose and indications unchanged; C/D must also keep functionality and performance unchanged. This is not a general stock grace after a new product-owner transfer or a substantive code/type change.

  • Existing stock and transition

A/B cessation or bankruptcy is a separate stock procedure

Fact-level verified

The retained A/B procedure in2075/QĐ-BYT requires the holder/distributor commitment dossier no later than60 days after the specified cessation, bankruptcy or dissolution event. The provincial health authority answers within 15 working days of a valid dossier; continued circulation is limited to24 months under the stated warranty/maintenance/material-support commitments, including the eight-year support wording and its exceptions. This is not an ordinary rename or transfer grace.

Conditions
  • This record is A/B only; it does not inherit a C/D procedure.
  • Use the current prescribed form where applicable; the historical administrative decision and later form framework are distinct.
  • Free sale certificate impact

Documents when the change triggers a new route

Fact-level verified

A fresh A/B dossier under 26-27 includes the applicable ISO 13485, owner authorisation, warranty evidence, technical description/standards, IFU, label and current imported-device CFS. Reagent/calibrator/control IVDs have their specifically listed technical and quality evidence. A new C/D dossier follows its Article 30 route and31 document/legalisation requirements, including the applicable CSDT and IVD quality certificate branches. Apply current Circular44 forms and owner-LOA/warranty templates.

Conditions
  • Only apply a new-dossier checklist where the actual change triggers that route; it is not the materials list for every label notification.
  • Warranty and route-specific exemptions must be preserved.
  • Free sale certificate impact

Separate A/B export CFS application

Fact-level verified

The retained A/B CFS procedure in2075/QĐ-BYT uses the provincial health authority, an application with owner/manufacturer/device/brand/code/circulation-number information and valid ISO 13485 evidence in the prescribed form. The procedure gives up to three working days from a complete proper dossier, with inspection possible where document review is insufficient. It is an export certificate requested to meet an importing-country requirement, not an automatic reissue after every logo or name edit.

Conditions
  • This A/B procedure is retained separately from the replaced C/D procedures.
  • The printed ISO1348 typo on physical16 is read with ISO 13485 on17; no raw text rewritten.
  • Free sale certificate impact

Separate C/D export CFS application

Fact-level verified

The C/D CFS procedure in3618/QĐ-BYT directs Form 11 under Circular44/2025 and the quality-certificate evidence to IMDA. It gives up to three working days from a complete proper dossier, allows inspection where needed and lists a VND 500000 export-dossier fee in the temporary fee framework. The form distinguishes owner, applicant, manufacturer, device type/code and circulation number. It is separate from change notification and does not itself require CFS reissue for every change.

Conditions
  • The listed VND 500000 is read in the 64/2025 reduction window through31 December2026, not a perpetual fee.
  • Labels and identifiers

IVD labels and Vietnamese instructions

Fact-level verified

An IVD circulating in Vietnam must meet Article22 label requirements and have Vietnamese instructions for use, with the stated warranty-information exceptions. Where IFU or warranty information is provided electronically rather than accompanying the device, the label must clearly show how to retrieve it. A brand, owner or REF change must be aligned with the actual label and current dossier; the language rule does not itself decide the filing route.

How do I update a manufacturer's name without changing the legal entity?

The same legal manufacturer changes its name, potentially alongside the device brand. A transfer to another legal entity is a separate question; permission to combine filings needs its own evidence.

  • Filing route and prior approval
  • Change-specific review time

Class A/B updates and fresh-declaration triggers

Fact-level verified

For Class A/B devices and IVDs, Article28(4) lists name/address updates for the product owner or circulation-number holder and manufacturer name/address information, plus qualifying label/IFU changes. Notify with related documents and update the public dossier within five working days after the change. A new product owner, device kind/type/purpose, added manufacturing site or added product code instead triggers a fresh declaration under 28(3).

Conditions
  • Label/IFU route requires unchanged intended purpose and indications.
  • A commercial brand is not automatically a new device type or product owner.
  • Filing route and prior approval
  • Change-specific review time

Class C/D updates and new-registration triggers

Fact-level verified

For Class C/D devices and IVDs, Article 32(7) lists owner/holder name and address, manufacturer name/address, packaging, warranty and qualifying label/IFU updates. Notify with related documents and update the public dossier within ten working days. Article29(1)(b) requires a new circulation number for the listed substantive changes, including a new product owner or added product code, and changes outside32(7).

Conditions
  • Label/IFU updates require unchanged purpose, indications, functionality and performance.
  • Ten working days is the holder notification deadline, not an authority approval SLA.
  • Filing route and prior approval
  • Supporting documents

Current update forms and supporting evidence

Fact-level verified

Circular44/2025 Form 13(A/B) and Form 14(C/D) identify the existing number and show previously declared/issued information beside updated information, with related documents and a signed/stamped or digital-signature commitment. Update all affected dossier evidence consistently; these forms are not a transfer approval or a replacement for a new application when Article28(3) or29(1)(b) is triggered.

  • Labels and identifiers

REF mapping and an actual registered code change

Fact-level verified

First map a commercial order REF to the declared or registered product code/type and label. An added product code triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); A/B reductions are specifically listed under 28(4)(g). Article 32a permits a priority request where the old code was discontinued and the prescribed device-type facts remain unchanged. Its ten-working-day decision is priority acceptance, not final registration approval.

  • Existing stock and transition

Existing stock after a qualifying label notice

Fact-level verified

Articles28(4)(e) and32(7)(e) permit devices manufactured before the holder gives the qualifying label-change notice to continue circulating with the information declared/registered and updated at manufacture. A/B must keep intended purpose and indications unchanged; C/D must also keep functionality and performance unchanged. This is not a general stock grace after a new product-owner transfer or a substantive code/type change.

  • Existing stock and transition

A/B cessation or bankruptcy is a separate stock procedure

Fact-level verified

The retained A/B procedure in2075/QĐ-BYT requires the holder/distributor commitment dossier no later than60 days after the specified cessation, bankruptcy or dissolution event. The provincial health authority answers within 15 working days of a valid dossier; continued circulation is limited to24 months under the stated warranty/maintenance/material-support commitments, including the eight-year support wording and its exceptions. This is not an ordinary rename or transfer grace.

Conditions
  • This record is A/B only; it does not inherit a C/D procedure.
  • Use the current prescribed form where applicable; the historical administrative decision and later form framework are distinct.
  • Free sale certificate impact

Documents when the change triggers a new route

Fact-level verified

A fresh A/B dossier under 26-27 includes the applicable ISO 13485, owner authorisation, warranty evidence, technical description/standards, IFU, label and current imported-device CFS. Reagent/calibrator/control IVDs have their specifically listed technical and quality evidence. A new C/D dossier follows its Article 30 route and31 document/legalisation requirements, including the applicable CSDT and IVD quality certificate branches. Apply current Circular44 forms and owner-LOA/warranty templates.

Conditions
  • Only apply a new-dossier checklist where the actual change triggers that route; it is not the materials list for every label notification.
  • Warranty and route-specific exemptions must be preserved.
  • Free sale certificate impact

Separate A/B export CFS application

Fact-level verified

The retained A/B CFS procedure in2075/QĐ-BYT uses the provincial health authority, an application with owner/manufacturer/device/brand/code/circulation-number information and valid ISO 13485 evidence in the prescribed form. The procedure gives up to three working days from a complete proper dossier, with inspection possible where document review is insufficient. It is an export certificate requested to meet an importing-country requirement, not an automatic reissue after every logo or name edit.

Conditions
  • This A/B procedure is retained separately from the replaced C/D procedures.
  • The printed ISO1348 typo on physical16 is read with ISO 13485 on17; no raw text rewritten.
  • Free sale certificate impact

Separate C/D export CFS application

Fact-level verified

The C/D CFS procedure in3618/QĐ-BYT directs Form 11 under Circular44/2025 and the quality-certificate evidence to IMDA. It gives up to three working days from a complete proper dossier, allows inspection where needed and lists a VND 500000 export-dossier fee in the temporary fee framework. The form distinguishes owner, applicant, manufacturer, device type/code and circulation number. It is separate from change notification and does not itself require CFS reissue for every change.

Conditions
  • The listed VND 500000 is read in the 64/2025 reduction window through31 December2026, not a perpetual fee.
  • Labels and identifiers

IVD labels and Vietnamese instructions

Fact-level verified

An IVD circulating in Vietnam must meet Article22 label requirements and have Vietnamese instructions for use, with the stated warranty-information exceptions. Where IFU or warranty information is provided electronically rather than accompanying the device, the label must clearly show how to retrieve it. A brand, owner or REF change must be aligned with the actual label and current dossier; the language rule does not itself decide the filing route.

What changes when the manufacturer's office address changes?

An office address change for the same legal entity, potentially alongside name and brand changes. This does not cover moving a factory or manufacturing site, and a combined filing cannot be assumed.

  • Filing route and prior approval
  • Change-specific review time

Class A/B updates and fresh-declaration triggers

Fact-level verified

For Class A/B devices and IVDs, Article28(4) lists name/address updates for the product owner or circulation-number holder and manufacturer name/address information, plus qualifying label/IFU changes. Notify with related documents and update the public dossier within five working days after the change. A new product owner, device kind/type/purpose, added manufacturing site or added product code instead triggers a fresh declaration under 28(3).

Conditions
  • Label/IFU route requires unchanged intended purpose and indications.
  • A commercial brand is not automatically a new device type or product owner.
  • Filing route and prior approval
  • Change-specific review time

Class C/D updates and new-registration triggers

Fact-level verified

For Class C/D devices and IVDs, Article 32(7) lists owner/holder name and address, manufacturer name/address, packaging, warranty and qualifying label/IFU updates. Notify with related documents and update the public dossier within ten working days. Article29(1)(b) requires a new circulation number for the listed substantive changes, including a new product owner or added product code, and changes outside32(7).

Conditions
  • Label/IFU updates require unchanged purpose, indications, functionality and performance.
  • Ten working days is the holder notification deadline, not an authority approval SLA.
  • Filing route and prior approval
  • Supporting documents

Current update forms and supporting evidence

Fact-level verified

Circular44/2025 Form 13(A/B) and Form 14(C/D) identify the existing number and show previously declared/issued information beside updated information, with related documents and a signed/stamped or digital-signature commitment. Update all affected dossier evidence consistently; these forms are not a transfer approval or a replacement for a new application when Article28(3) or29(1)(b) is triggered.

  • Labels and identifiers

REF mapping and an actual registered code change

Fact-level verified

First map a commercial order REF to the declared or registered product code/type and label. An added product code triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); A/B reductions are specifically listed under 28(4)(g). Article 32a permits a priority request where the old code was discontinued and the prescribed device-type facts remain unchanged. Its ten-working-day decision is priority acceptance, not final registration approval.

  • Existing stock and transition

Existing stock after a qualifying label notice

Fact-level verified

Articles28(4)(e) and32(7)(e) permit devices manufactured before the holder gives the qualifying label-change notice to continue circulating with the information declared/registered and updated at manufacture. A/B must keep intended purpose and indications unchanged; C/D must also keep functionality and performance unchanged. This is not a general stock grace after a new product-owner transfer or a substantive code/type change.

  • Existing stock and transition

A/B cessation or bankruptcy is a separate stock procedure

Fact-level verified

The retained A/B procedure in2075/QĐ-BYT requires the holder/distributor commitment dossier no later than60 days after the specified cessation, bankruptcy or dissolution event. The provincial health authority answers within 15 working days of a valid dossier; continued circulation is limited to24 months under the stated warranty/maintenance/material-support commitments, including the eight-year support wording and its exceptions. This is not an ordinary rename or transfer grace.

Conditions
  • This record is A/B only; it does not inherit a C/D procedure.
  • Use the current prescribed form where applicable; the historical administrative decision and later form framework are distinct.
  • Free sale certificate impact

Documents when the change triggers a new route

Fact-level verified

A fresh A/B dossier under 26-27 includes the applicable ISO 13485, owner authorisation, warranty evidence, technical description/standards, IFU, label and current imported-device CFS. Reagent/calibrator/control IVDs have their specifically listed technical and quality evidence. A new C/D dossier follows its Article 30 route and31 document/legalisation requirements, including the applicable CSDT and IVD quality certificate branches. Apply current Circular44 forms and owner-LOA/warranty templates.

Conditions
  • Only apply a new-dossier checklist where the actual change triggers that route; it is not the materials list for every label notification.
  • Warranty and route-specific exemptions must be preserved.
  • Free sale certificate impact

Separate A/B export CFS application

Fact-level verified

The retained A/B CFS procedure in2075/QĐ-BYT uses the provincial health authority, an application with owner/manufacturer/device/brand/code/circulation-number information and valid ISO 13485 evidence in the prescribed form. The procedure gives up to three working days from a complete proper dossier, with inspection possible where document review is insufficient. It is an export certificate requested to meet an importing-country requirement, not an automatic reissue after every logo or name edit.

Conditions
  • This A/B procedure is retained separately from the replaced C/D procedures.
  • The printed ISO1348 typo on physical16 is read with ISO 13485 on17; no raw text rewritten.
  • Free sale certificate impact

Separate C/D export CFS application

Fact-level verified

The C/D CFS procedure in3618/QĐ-BYT directs Form 11 under Circular44/2025 and the quality-certificate evidence to IMDA. It gives up to three working days from a complete proper dossier, allows inspection where needed and lists a VND 500000 export-dossier fee in the temporary fee framework. The form distinguishes owner, applicant, manufacturer, device type/code and circulation number. It is separate from change notification and does not itself require CFS reissue for every change.

Conditions
  • The listed VND 500000 is read in the 64/2025 reduction window through31 December2026, not a perpetual fee.
  • Labels and identifiers

IVD labels and Vietnamese instructions

Fact-level verified

An IVD circulating in Vietnam must meet Article22 label requirements and have Vietnamese instructions for use, with the stated warranty-information exceptions. Where IFU or warranty information is provided electronically rather than accompanying the device, the label must clearly show how to retrieve it. A brand, owner or REF change must be aligned with the actual label and current dossier; the language rule does not itself decide the filing route.

Does a catalogue or reference code change affect registration or UDI?

Check which identifier actually changes. A commercial catalogue, REF or order code is not automatically a device model, registered identifier, GTIN or UDI-DI. Rules for one identifier do not establish the route for another.

  • Filing route and prior approval
  • Change-specific review time

Class A/B updates and fresh-declaration triggers

Fact-level verified

For Class A/B devices and IVDs, Article28(4) lists name/address updates for the product owner or circulation-number holder and manufacturer name/address information, plus qualifying label/IFU changes. Notify with related documents and update the public dossier within five working days after the change. A new product owner, device kind/type/purpose, added manufacturing site or added product code instead triggers a fresh declaration under 28(3).

Conditions
  • Label/IFU route requires unchanged intended purpose and indications.
  • A commercial brand is not automatically a new device type or product owner.
  • Filing route and prior approval
  • Change-specific review time

Class C/D updates and new-registration triggers

Fact-level verified

For Class C/D devices and IVDs, Article 32(7) lists owner/holder name and address, manufacturer name/address, packaging, warranty and qualifying label/IFU updates. Notify with related documents and update the public dossier within ten working days. Article29(1)(b) requires a new circulation number for the listed substantive changes, including a new product owner or added product code, and changes outside32(7).

Conditions
  • Label/IFU updates require unchanged purpose, indications, functionality and performance.
  • Ten working days is the holder notification deadline, not an authority approval SLA.
  • Filing route and prior approval
  • Supporting documents

Current update forms and supporting evidence

Fact-level verified

Circular44/2025 Form 13(A/B) and Form 14(C/D) identify the existing number and show previously declared/issued information beside updated information, with related documents and a signed/stamped or digital-signature commitment. Update all affected dossier evidence consistently; these forms are not a transfer approval or a replacement for a new application when Article28(3) or29(1)(b) is triggered.

  • Filing route and prior approval
  • Labels and identifiers

REF mapping and an actual registered code change

Fact-level verified

First map a commercial order REF to the declared or registered product code/type and label. An added product code triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); A/B reductions are specifically listed under 28(4)(g). Article 32a permits a priority request where the old code was discontinued and the prescribed device-type facts remain unchanged. Its ten-working-day decision is priority acceptance, not final registration approval.

  • Supporting documents
  • Free sale certificate impact

Documents when the change triggers a new route

Fact-level verified

A fresh A/B dossier under 26-27 includes the applicable ISO 13485, owner authorisation, warranty evidence, technical description/standards, IFU, label and current imported-device CFS. Reagent/calibrator/control IVDs have their specifically listed technical and quality evidence. A new C/D dossier follows its Article 30 route and31 document/legalisation requirements, including the applicable CSDT and IVD quality certificate branches. Apply current Circular44 forms and owner-LOA/warranty templates.

Conditions
  • Only apply a new-dossier checklist where the actual change triggers that route; it is not the materials list for every label notification.
  • Warranty and route-specific exemptions must be preserved.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific review time

C/D clocks only after a new-route trigger

Fact-level verified

Where the change requires a new C/D application, Article 32 distinguishes30 calendar days for the specified Article 30(1)-(2) routes, ten working days for the fast and emergency routes, and45 calendar days for the other-device route, from a complete valid dossier including fee evidence if no amendment is requested. Deficiency-notice periods and90-day applicant-response/repeated-amendment limits are separate. None of these clocks is a review period for a five/ten-day change notification.

Conditions
  • Select the actual new-application category and its complete-dossier conditions.
  • A priority-request decision within ten working days is not a circulation-number grant.
  • Existing stock and transition

Existing stock after a qualifying label notice

Fact-level verified

Articles28(4)(e) and32(7)(e) permit devices manufactured before the holder gives the qualifying label-change notice to continue circulating with the information declared/registered and updated at manufacture. A/B must keep intended purpose and indications unchanged; C/D must also keep functionality and performance unchanged. This is not a general stock grace after a new product-owner transfer or a substantive code/type change.

  • Existing stock and transition

A/B cessation or bankruptcy is a separate stock procedure

Fact-level verified

The retained A/B procedure in2075/QĐ-BYT requires the holder/distributor commitment dossier no later than60 days after the specified cessation, bankruptcy or dissolution event. The provincial health authority answers within 15 working days of a valid dossier; continued circulation is limited to24 months under the stated warranty/maintenance/material-support commitments, including the eight-year support wording and its exceptions. This is not an ordinary rename or transfer grace.

Conditions
  • This record is A/B only; it does not inherit a C/D procedure.
  • Use the current prescribed form where applicable; the historical administrative decision and later form framework are distinct.
  • Free sale certificate impact

Separate A/B export CFS application

Fact-level verified

The retained A/B CFS procedure in2075/QĐ-BYT uses the provincial health authority, an application with owner/manufacturer/device/brand/code/circulation-number information and valid ISO 13485 evidence in the prescribed form. The procedure gives up to three working days from a complete proper dossier, with inspection possible where document review is insufficient. It is an export certificate requested to meet an importing-country requirement, not an automatic reissue after every logo or name edit.

Conditions
  • This A/B procedure is retained separately from the replaced C/D procedures.
  • The printed ISO1348 typo on physical16 is read with ISO 13485 on17; no raw text rewritten.
  • Free sale certificate impact

Separate C/D export CFS application

Fact-level verified

The C/D CFS procedure in3618/QĐ-BYT directs Form 11 under Circular44/2025 and the quality-certificate evidence to IMDA. It gives up to three working days from a complete proper dossier, allows inspection where needed and lists a VND 500000 export-dossier fee in the temporary fee framework. The form distinguishes owner, applicant, manufacturer, device type/code and circulation number. It is separate from change notification and does not itself require CFS reissue for every change.

Conditions
  • The listed VND 500000 is read in the 64/2025 reduction window through31 December2026, not a perpetual fee.
  • Labels and identifiers

IVD labels and Vietnamese instructions

Fact-level verified

An IVD circulating in Vietnam must meet Article22 label requirements and have Vietnamese instructions for use, with the stated warranty-information exceptions. Where IFU or warranty information is provided electronically rather than accompanying the device, the label must clearly show how to retrieve it. A brand, owner or REF change must be aligned with the actual label and current dossier; the language rule does not itself decide the filing route.

Can several changes be filed together?

Changes to brand, manufacturer name, office address and reference codes may occur together, including with a real transfer to another legal manufacturer, registration holder or owner. Assess transfer with each single change, and transfer with brand plus reference, manufacturer name plus reference, or office address plus reference changes: seven transfer combinations in total. Evidence must establish the exact combination and the order of filings and approvals. These combinations and their sequence are not all verified by the rules below; a rule for one change does not prove that a single application, fee or review period covers the combination.

  • Filing route and prior approval
  • Change-specific review time

Class A/B updates and fresh-declaration triggers

Fact-level verified

For Class A/B devices and IVDs, Article28(4) lists name/address updates for the product owner or circulation-number holder and manufacturer name/address information, plus qualifying label/IFU changes. Notify with related documents and update the public dossier within five working days after the change. A new product owner, device kind/type/purpose, added manufacturing site or added product code instead triggers a fresh declaration under 28(3).

Conditions
  • Label/IFU route requires unchanged intended purpose and indications.
  • A commercial brand is not automatically a new device type or product owner.
  • Filing route and prior approval
  • Change-specific review time

Class C/D updates and new-registration triggers

Fact-level verified

For Class C/D devices and IVDs, Article 32(7) lists owner/holder name and address, manufacturer name/address, packaging, warranty and qualifying label/IFU updates. Notify with related documents and update the public dossier within ten working days. Article29(1)(b) requires a new circulation number for the listed substantive changes, including a new product owner or added product code, and changes outside32(7).

Conditions
  • Label/IFU updates require unchanged purpose, indications, functionality and performance.
  • Ten working days is the holder notification deadline, not an authority approval SLA.
  • Filing route and prior approval
  • Supporting documents

Current update forms and supporting evidence

Fact-level verified

Circular44/2025 Form 13(A/B) and Form 14(C/D) identify the existing number and show previously declared/issued information beside updated information, with related documents and a signed/stamped or digital-signature commitment. Update all affected dossier evidence consistently; these forms are not a transfer approval or a replacement for a new application when Article28(3) or29(1)(b) is triggered.

  • Filing route and prior approval
  • Labels and identifiers

REF mapping and an actual registered code change

Fact-level verified

First map a commercial order REF to the declared or registered product code/type and label. An added product code triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); A/B reductions are specifically listed under 28(4)(g). Article 32a permits a priority request where the old code was discontinued and the prescribed device-type facts remain unchanged. Its ten-working-day decision is priority acceptance, not final registration approval.

  • Filing route and prior approval

A new product owner is different from a name update

Fact-level verified

A real change of product owner triggers a fresh A/B declaration or C/D circulation-number application under 28(3)/29(1)(b); a name-only update of the same owner is different. The local declarant/registrant must be eligible under Article 25 and hold the applicable owner authorisation and warranty support. A different local importer or registrant is separately recognised in the conditional priority process of32a; it is not an unrestricted transfer of the existing number.

  • Supporting documents
  • Free sale certificate impact

Documents when the change triggers a new route

Fact-level verified

A fresh A/B dossier under 26-27 includes the applicable ISO 13485, owner authorisation, warranty evidence, technical description/standards, IFU, label and current imported-device CFS. Reagent/calibrator/control IVDs have their specifically listed technical and quality evidence. A new C/D dossier follows its Article 30 route and31 document/legalisation requirements, including the applicable CSDT and IVD quality certificate branches. Apply current Circular44 forms and owner-LOA/warranty templates.

Conditions
  • Only apply a new-dossier checklist where the actual change triggers that route; it is not the materials list for every label notification.
  • Warranty and route-specific exemptions must be preserved.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific government fees

Conditions for this question

  • Only where the actual change triggers a new declaration or circulation-number dossier; select the applicable class.
  • Temporary50% fee window1 July2025 through31 December2026; no ordinary-notification fee is inferred.
  • Change-specific review time

C/D clocks only after a new-route trigger

Fact-level verified

Where the change requires a new C/D application, Article 32 distinguishes30 calendar days for the specified Article 30(1)-(2) routes, ten working days for the fast and emergency routes, and45 calendar days for the other-device route, from a complete valid dossier including fee evidence if no amendment is requested. Deficiency-notice periods and90-day applicant-response/repeated-amendment limits are separate. None of these clocks is a review period for a five/ten-day change notification.

Conditions
  • Select the actual new-application category and its complete-dossier conditions.
  • A priority-request decision within ten working days is not a circulation-number grant.
  • Existing stock and transition

Existing stock after a qualifying label notice

Fact-level verified

Articles28(4)(e) and32(7)(e) permit devices manufactured before the holder gives the qualifying label-change notice to continue circulating with the information declared/registered and updated at manufacture. A/B must keep intended purpose and indications unchanged; C/D must also keep functionality and performance unchanged. This is not a general stock grace after a new product-owner transfer or a substantive code/type change.

  • Existing stock and transition

A/B cessation or bankruptcy is a separate stock procedure

Fact-level verified

The retained A/B procedure in2075/QĐ-BYT requires the holder/distributor commitment dossier no later than60 days after the specified cessation, bankruptcy or dissolution event. The provincial health authority answers within 15 working days of a valid dossier; continued circulation is limited to24 months under the stated warranty/maintenance/material-support commitments, including the eight-year support wording and its exceptions. This is not an ordinary rename or transfer grace.

Conditions
  • This record is A/B only; it does not inherit a C/D procedure.
  • Use the current prescribed form where applicable; the historical administrative decision and later form framework are distinct.
  • Free sale certificate impact

Separate A/B export CFS application

Fact-level verified

The retained A/B CFS procedure in2075/QĐ-BYT uses the provincial health authority, an application with owner/manufacturer/device/brand/code/circulation-number information and valid ISO 13485 evidence in the prescribed form. The procedure gives up to three working days from a complete proper dossier, with inspection possible where document review is insufficient. It is an export certificate requested to meet an importing-country requirement, not an automatic reissue after every logo or name edit.

Conditions
  • This A/B procedure is retained separately from the replaced C/D procedures.
  • The printed ISO1348 typo on physical16 is read with ISO 13485 on17; no raw text rewritten.
  • Free sale certificate impact

Separate C/D export CFS application

Fact-level verified

The C/D CFS procedure in3618/QĐ-BYT directs Form 11 under Circular44/2025 and the quality-certificate evidence to IMDA. It gives up to three working days from a complete proper dossier, allows inspection where needed and lists a VND 500000 export-dossier fee in the temporary fee framework. The form distinguishes owner, applicant, manufacturer, device type/code and circulation number. It is separate from change notification and does not itself require CFS reissue for every change.

Conditions
  • The listed VND 500000 is read in the 64/2025 reduction window through31 December2026, not a perpetual fee.
  • Labels and identifiers

IVD labels and Vietnamese instructions

Fact-level verified

An IVD circulating in Vietnam must meet Article22 label requirements and have Vietnamese instructions for use, with the stated warranty-information exceptions. Where IFU or warranty information is provided electronically rather than accompanying the device, the label must clearly show how to retrieve it. A brand, owner or REF change must be aligned with the actual label and current dossier; the language rule does not itself decide the filing route.

Regulation codes

What these codes are

Each row above represents one regulatory instrument. Its code is the authority’s identifier. A regulation page collects the metadata and official source; when readable HTML is available, article links can open and highlight the exact cited passage.

Use this market context

Continue from regulations into practical research

Keep Vietnam as the target market while you move into registration records, classification, cross-country product research, or pathway planning.

Keep researching this market
View the Vietnam resource hub →
Compare regulations across all countries →
Tracked from official Ministry of Health publications · row IDs are stable — cite as regulations:vietnam:circular-44-2025-device-delegation-forms