Pure Global AI
ANVISA · structured requirements

🇧🇷 Brazil IVD regulatory data

Explore the IVD requirements currently available for Brazil, organized by topic and linked to official sources.

25 facts8 dimensions21 official sourceslatest verification 2026-10-21
Explore questions and sources →

Common questions about changing a registered IVD in Brazil. Each question separates published rules from details still awaiting verification.

Change control

Does the event require internal documentation, notice, prior approval, transfer, or a new application?

Compare countries

Interdependent alterations follow the approval-required petition

changes.dependent-change-filing-ivd
Fact-level verified

An immediate alteration that is interdependent with an approval-required alteration must be filed jointly with it and incorporated into that petition. Approval-required changes take effect only after the final decision is published in the Diário Oficial da União.

Transfer documents and pending applications

changes.holder-transfer-documents-sequence
Fact-level verified

Transfer requires the signed petition form, GRU proof of TFVS payment/exemption, Annex I transaction declaration and updated operating/sanitary licence. Pending initial applications are updated by an amendment rather than a transfer of an issued registration. Pending post-registration petitions transfer only when declared in Annex I; unlisted petitions are closed. Holder-only label/IFU updates may be implemented after transfer approval.

Registered holder succession differs from a notified product

changes.holder-transfer-route
Fact-level verified

For an unchanged registered product, the successor’s holder-transfer petition and predecessor’s cancellation petition must be filed concurrently within 180 days of the registered corporate act or asset-transfer contract, subject to the separate Mercosur trigger. Late petitions are refused. Products subject to notification or exemption are not transferred: the successor makes a new notification or regularization. A simple same-person corporate-name change is excluded from this transaction regime.

Conditions
  • Determine whether the foreign manufacturer, Brazilian holder, or both actually change legal person. A foreign corporate transaction does not by itself transfer the Brazilian registration.

Registered IVD commercial-name checklist

changes.ivd-commercial-name-materials
Fact-level verified

Registered IVD commercial-name change subject 8007 requires updated primary/secondary label images, updated IFU/manual, a digitally signed technical-responsible declaration listing the changes, and affected portions of the technical dossier.

IVD product and family transfer lists

changes.ivd-holder-transfer-checklists
Fact-level verified

IVD transfer subject 80074 (product) and80078 (family) require the RDC 903 Annex I declaration digitally signed by legal and technical responsibles, the updated operating/sanitary licence and an Anvisa GMP certificate in the successor’s name or its application protocol. Parent RDC 903 Art. 30 also requires the petition form and TFVS payment/exemption. The family subject is not proof that an arbitrary collection of products qualifies as a family.

IVD legal-manufacturer replacement without process change

changes.ivd-new-manufacturer-materials
Fact-level verified

Subject8011 requires updated labels and IFU, a technical-responsible signed change declaration identifying the manufacturer, the apostilled/consularized imported-manufacturer authorization and GMP undertaking, and affected dossier sections. Multiple legal manufacturers need same-group proof. If the legal manufacturer is itself the factory, include the updated Anvisa GMP certificate or protocol and also file the approval-required manufacturing-site alteration.

Conditions
  • The manufacturing process must remain unchanged; corporate succession does not dispense with the manufacturer/site branch.

Notified IVD alteration materials

changes.ivd-notified-materials
Fact-level verified

For subject 80198, submit primary/secondary labels and an updated IFU highlighting changes, or justified no-impact documents, plus the technical-responsible signed change declaration. Affected technical-dossier portions are required by this list for class II. A change of notification holder is governed separately by the new-notification rule.

Foreign IVD corporate-name change is a narrow subject

changes.ivd-same-person-name-materials
Fact-level verified

Subject8020 is exclusively a foreign legal-manufacturer or manufacturing-unit corporate-name change. Supply label/IFU updates or justified no-impact statements, the manufacturer’s reason document, the imported legal-manufacturer authorization where its name changes, the updated Anvisa GMP certificate or protocol where the plant name changes, and affected dossier sections. Address/process changes use their pertinent subjects; corporate purchase, sale, merger or division is a manufacturer/site change, not this name-only subject.

Immediate subjects distinguish names from identifiers

changes.named-immediate-subjects
Fact-level verified

IN 74 Annex II lists commercial-name changes and foreign legal-manufacturer or factory corporate-name changes as immediate subjects. For equipment and materials it also expressly lists commercial-model name/code changes. The IVD rows separately list commercial name, commercial presentation and legal manufacturer without a manufacturing-process change; the equipment model/code wording must not be applied automatically to an IVD orderable REF.

Conditions
  • Use the actual product sector and its petition subject; an internal order code is not automatically the commercial model or registered presentation.

Materials for an ordinary alteration

changes.ordinary-change-materials-ivd
Fact-level verified

File the applicable petition subject, the fee or exemption where applicable, a declaration listing the requested alterations, and documentary evidence supporting them. A single label mock-up does not replace the subject-specific technical dossier or manufacturer evidence.

Classify an ordinary alteration before implementation

changes.ordinary-change-route-ivd
Fact-level verified

Changes to notification or registration are approval-required, immediate, or non-reportable. Classes I/II use immediate implementation except non-reportable changes. Minor non-technical images, layout, symbols or text without added risk, and contact/postal-address updates, can be non-reportable when they do not change the design; control them in the holder’s quality system and incorporate them into later petitions. A trade-name change is not automatically a logo-artwork exemption.

Conditions
  • Device identity, intended purpose, manufacturing process and legal person must be established. A new factory or legal manufacturer must be assessed separately.

Registered change petitions do not absorb unrequested subjects

changes.registered-filing-subject-scope
Fact-level verified

The official registered-device alteration FAQ says that a petition permits only its requested alteration item and other inserted alterations are disregarded. This must be read with the legal rule requiring an interdependent immediate change to accompany the approval-required change. It does not authorize combining every name/address/REF/holder change into one fee or decision.

Corporate operations can require separate AFE and GMP updates

changes.transaction-certification-evidence
Fact-level verified

RDC 903 Arts. 7–14 require the applicable company-authorization and GMP/distribution-certificate updates following corporate/commercial operations. A new legal person or unregularized successor needs initial AFE/AE as applicable. For a qualifying unchanged production line, CBPF update preserves certificate validity; an exclusively foreign operation is petitioned by the current certification applicant. Art. 13 lists the form, existing certificate, transaction declaration, applicable updated AFE publication, and successor-country GMP certificate or competent-authority transaction attestation for a foreign operation.

Conditions
  • Actual technical/sanitary characteristics and the entire affected production line must meet Art. 12. These establishment/certification acts are distinct from product-holder transfer and product alterations.

Classification rules

What local class follows from which rules and decisive product facts?

Compare countries

Fees

What regulator fee applies to this class, route, event, and date?

Compare countries

TFVS depends on the alteration subject and company size

changes.change-specific-tfvs
Fact-level verified

RDC 857 Annex I7.9.1 sets product-registration alteration/inclusion factor 738 DV2 at BRL3514.32,2987.17,2460.02,1405.73,351.43 or175.72 by company-size column. The separate label/IFU alteration item7.9.2 factor 742 DV0 is exempt. Map the actual petition subject to its factor; a commercial-name or manufacturer change is not automatically a label-only exempt petition.

Conditions
  • Company size, subject code and any statutory exemption determine the actual GRU. This is not a portfolio-wide single fee.

Transfer TFVS is affected by successor size

changes.holder-transfer-tfvs
Fact-level verified

RDC 857 Art. 10 conditions holder transfer on any positive TFVS difference associated with the successor’s economic size and provides no refund if it is smaller. Simultaneous renewal and later transfer use the specified size-reference dates; a later transfer also triggers the alteration charge. Calculate the actual petition and size difference rather than assuming an ordinary label-only exemption.

Label, IFU & language

Which label and IFU elements, languages, symbols, and translation controls apply?

Compare countries

Transfer stock has its own effective-date sequence

changes.holder-transfer-stock
Fact-level verified

The successor is responsible for remaining finished stock. Finished stock produced before the individual transfer/cancellation resolutions take effect may be imported or sold for at most180 days after that effective date. Outdated packaging cannot be used for new lots produced afterwards. Unless otherwise stated, those individual resolutions take effect90 days after publication. These180/90-day periods are stock/effect rules, not agency review periods.

Finished stock and unused label stock have different limits

changes.ordinary-stock-ivd
Fact-level verified

For an ordinary alteration, old and new finished-device versions may be imported and sold until expiry or the end of useful life. Unused packaging, labels and IFUs may be exhausted for 120 days from publication of the alteration. Changes made to resolve safety or performance problems are excluded from both permissions. The publication trigger does not create an implementation-date clock for an unpublished non-reportable artwork change.

Conditions
  • These are ordinary alteration rules. Holder transfers follow RDC 903 instead.

Official forms & portals

Which current form, portal, account, and submission package must be used?

Compare countries

IVD manufacturer authorization must match the parties

changes.imported-ivd-authorization-boundary
Fact-level verified

RDC 830 Arts. 13–14 require the imported-IVD legal-manufacturer authorization naming the full manufacturer and applicant names/addresses, representation/commercialization rights and GMP undertaking; use apostille/consularization and Portuguese, English, Spanish or sworn translation, within two years if validity is unstated. Art. 14 does not list a blanket CFS item. Subjects8011/8020 require the specific updated authorization; this is not a general CFS-reissue duty.

Reliance & recognition

Which foreign decisions or evidence can be reused, with what effect and conditions?

Compare countries

Existing records include acceptance, restrictions and evidence reuse. The applicable product scope and conditions are preserved below; a reference does not by itself confer market access.

Brazil approvals and evidence in other markets (19 records)

ArmeniaBrazil ANVISA · EU conformity assessment · US FDA · Health Canada · Singapore HSA · UK MHRA · South Korea MFDS · Japan MHLW / PMDA · NMPA · Australia TGA · Türkiye conformity assessment

Prior approval / evidence record

Import of an unregistered device requires proof of authorisation in the country of manufacture or in an IMDRF member country

reliance.origin-country-or-imdrf-authorisation-evidence-for-unregistered-import
Fact-level verified
Statement

A device that has no Armenian state registration can still be imported, but the import (conformity) certificate file must contain a document confirming that the device is authorised for use — state registration or free circulation — in its country of manufacture or in an IMDRF member country, or a reasoned reference to such a document, including a Declaration of Conformity with references to the relevant registers. This is the origin-country free-sale certificate requirement: a Turkish, Korean, Chinese or European exporter must produce its home-country registration/free-sale evidence (or an IMDRF-country equivalent) even though the device is not registered in Armenia. The document is mandatory paperwork; the Armenian expert organisation still examines the file and the Ministry of Health still decides.

Source Approval

Registration / free circulation in the country of manufacture, or in any IMDRF member country — US FDA, EU member states (CE), Japan PMDA, Korea MFDS, China NMPA, Canada, Australia, Brazil, Singapore, UK — evidenced by a registration certificate, free-sale certificate or a Declaration of Conformity with register references

Edge Type

Origin Country Evidence

Market Access Strength

Evidence Only

Regulatory Layer

Import Control

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • The obligation attaches to the import (conformity) certificate for devices without Armenian state registration; for devices that do have Armenian state registration the equivalent item is a copy of the Armenian registration certificate, and the origin-country evidence is not required.
  • One of the ten statutory grounds for refusing the import certificate is that the imported device has no Armenian state registration, except in the cases the Law allows (Article 47.2(7)(8)). The origin/IMDRF evidence does not cure that ground where registration was required; it is the supporting document for the unregistered-device import cases the Law permits.
  • The file also requires, for every batch, a quality conformity certificate or equivalent, and the instructions for use or a reference to their electronic version (Annex 2, para. 2(2)(b), (c)).
  • The document list was extended by Government Decree No. 1731-Ն of 12.10.2023 and No. 1619-Ն of 17.10.2024.

Language: Armenian. Verbatim, Government Decree No. 429-Ն of 30.03.2023, Annex No. 2, para. 2(2)(a): "պետական գրանցում չունեցող բժշկական արտադրատեսակների համար՝ ա. բժշկական արտադրատեսակի արտադրող երկրում կամ Բժշկական արտադրատեսակների կարգավորող մարմինների միջազգային համաժողովի (IMDRF) անդամ երկրներում կիրառման թույլտվությունը (պետական գրանցումը, ազատ կիրառումը) հավաստող փաստաթուղթ կամ դրա վերաբերյալ փաստարկված տեղեկանք, այդ թվում՝ բժշկական արտադրատեսակների համապատասխանության հայտարարագիր (Declaration of Conformity) համապատասխան գրանցամատյանների հղումով". Translation: "for medical devices without state registration: a. a document confirming authorisation for use (state registration, free circulation) in the country of manufacture of the medical device or in member countries of the International Medical Device Regulators Forum (IMDRF), or a reasoned reference thereto, including a Declaration of Conformity for the medical device with reference to the relevant registers".

ArmeniaBrazil ANVISA · EU conformity assessment · US FDA · Health Canada · Singapore HSA · UK MHRA · South Korea MFDS · Japan MHLW / PMDA · NMPA · Australia TGA · IMDRF member authorities · WHO

Prior approval / evidence record

Simplified national registration for a device registered in an IMDRF member country or prequalified by WHO

reliance.imdrf-member-or-who-prequalified-simplified-registration
Fact-level verified
Statement

Armenia registers medical devices under two national procedures: a general procedure and a simplified procedure. The simplified procedure applies to a device that is registered in a country that is a member of the International Medical Device Regulators Forum (IMDRF) or that is prequalified by the World Health Organization. IMDRF members include the United States (FDA), the EU member states (CE marking), Japan (PMDA), Korea (MFDS), China (NMPA), Canada, Australia, Brazil, Singapore and the United Kingdom, so a US FDA 510(k)/PMA clearance, an EU CE mark, a Japan PMDA approval and a Korea MFDS approval all satisfy the gate. The device is still registered in Armenia by the Armenian authority — the foreign registration opens the shortened procedure, it does not replace the Armenian certificate.

Source Approval

Registration in any IMDRF member country — US FDA 510(k)/PMA, EU CE marking under MDR/IVDR (any EU member state), Japan PMDA, Korea MFDS, China NMPA, Health Canada, Australia TGA, Brazil ANVISA, Singapore HSA, UK MHRA — or WHO prequalification of the device

Edge Type

Abridged Or Recognition Route

Market Access Strength

facilitated

Regulatory Layer

Premarket Review

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • The provision is written as an annex to part 3 of the same article: 'under the procedure laid down by part 3 of this article' devices are registered under the general and simplified procedures. Part 3 is itself the Armenia-only route, and a footnote to Article 46 states that part 3 operates only until the end of the transitional period set by Article 11 of the EAEU Agreement of 23 December 2014 (footnote inserted by Article 3(2) of the Law of 5 December 2024 ՀՕ-502-Ն). The transitional period was extended by the Protocol signed in Moscow on 29 December 2025, which replaced '2025' with '2027' in the first paragraph of Article 11 of that Agreement and '2026' with '2028' in the third and fourth paragraphs.
  • Bounded claim: the Law names IMDRF membership and WHO prequalification as the gate for the simplified procedure. It does not name the FDA, the CE mark, the PMDA or the MFDS; those follow from their countries' IMDRF membership, not from the text.
  • The operational content of the 'simplified procedure' (dossier list, clocks, certificate form) sits in the Government procedure that Article 46(3) contemplates; that instrument was not located in this session (see unresolved: registration-pathways).
  • Devices are registered by the Ministry of Health (the լիազոր մարմին / authorised body) with the examination carried out by the expert organisation designated by Government decision (Article 46(2), (5)).

Language: Armenian. Verbatim, Article 46(4): "Սույն հոդվածի 3-րդ մասով սահմանված կարգի համաձայն՝ բժշկական արտադրատեսակները գրանցվում են ընդհանուր և պարզեցված ընթացակարգերով: Պարզեցված ընթացակարգը կիրառվում է բժշկական արտադրատեսակների շրջանառությունը կարգավորող մարմինների միջազգային համաժողովի (IMDRF) անդամ երկրում գրանցված կամ Առողջապահության համաշխարհային կազմակերպության նախաորակավորած բժշկական արտադրատեսակների համար:" Translation: "Under the procedure laid down by part 3 of this article, medical devices are registered under general and simplified procedures. The simplified procedure applies to medical devices registered in a member country of the International Medical Device Regulators Forum (IMDRF) or prequalified by the World Health Organization." Article 46 was amended by the Law of 5 December 2024 ՀՕ-502-Ն; the consolidated expression is the version in force from 31.05.2026.

ColombiaBrazil ANVISA

Prior approval / evidence record

ANVISA (Brazil)

Authority

ANVISA (Brazil)

Accepted

No

Benefit

Brazil is not on the INVIMA reference-country list and there is no device mutual recognition agreement in force

Timeline Savings

None

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

Dominican RepublicBrazil ANVISA

Prior approval / evidence record

PAHO/PARF regional reference authorities (ARNr) — ANMAT, ANVISA, CECMED, INVIMA, COFEPRIS

Authority

PAHO/PARF regional reference authorities (ARNr) — ANMAT, ANVISA, CECMED, INVIMA, COFEPRIS

Accepted

Yes

Benefit

Same simplified-procedure eligibility as the WHO Strict Authorities under Resolución No. 000004.

Timeline Savings

No published period.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

KuwaitHealth Canada · Japan MHLW / PMDA · UK MHRA · Brazil ANVISA · Australia TGA

Prior approval / evidence record

Health Canada, Japan MHLW/PMDA, UK MHRA, Brazil ANVISA and Australia TGA approvals

Authority

Health Canada, Japan MHLW/PMDA, UK MHRA, Brazil ANVISA and Australia TGA approvals

Accepted

Yes

Benefit

Also recognised reference authorities under the Abridged Review Pathway, on the same terms as the FDA and EU routes: identical product required, national requirements still assessed, final acceptance decided by the Administration.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

LebanonIMDRF member authorities

Prior approval / evidence record

GHTF/IMDRF member countries — free-sale certificate (شهادة بيع حر)

Authority

GHTF/IMDRF member countries — free-sale certificate (شهادة بيع حر)

Accepted

Yes

Benefit

A mandatory document rather than a route: Decision 1506/1 Art. Four requires the registration application to carry a free-sale certificate issued by a country belonging to the GHTF/IMDRF group, meaning the device is sold in one of those countries whatever its origin, and the Ministry's service records require a free-sale certificate with an ISO 13485 certificate where the goods are made outside the reference states or the listed documents cannot be produced. No examination period is shortened by it.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

MexicoNMPA · US FDA · EU conformity assessment · Australia TGA · Health Canada · Japan MHLW / PMDA · UK MHRA · Swissmedic · South Korea MFDS · Singapore HSA · Brazil ANVISA · IMDRF member authorities · MDSAP · WHO

Prior approval / evidence record

Vía regulatoria abreviada — ARR equivalence (COFEPRIS-04-050)

Name

Vía regulatoria abreviada — ARR equivalence (COFEPRIS-04-050)

Description

The single reliance route since the DOF Acuerdo of 18 July 2025, which took effect 30 working days after publication and abrogated every individual equivalence agreement issued between 2012 and June 2025 — the separate FDA, Swissmedic, European Commission, Health Canada, TGA and WHO prequalification acuerdos no longer exist. COFEPRIS now recognises the decision of any Reference Regulatory Authority from a country sitting on the IMDRF Management Committee, and MDSAP full membership for GMP certificates. The dossier drops to an administrative-legal section plus technical information under RIS Art. 31.

Timeline Reduction

Resolution within a maximum of 30 working days

Eligibility
  • Prior authorisation by a Reference Regulatory Authority in one of the twelve IMDRF Management Committee jurisdictions: Australia, Brazil, Canada, China, the European Union, Japan, Russia, Singapore, South Korea, Switzerland, the United Kingdom, the United States
  • MDSAP full members are recognised for the good-manufacturing-practice certificate
  • Filed under homoclave COFEPRIS-04-050 rather than the ordinary COFEPRIS-04-060 registration
  • Post-market surveillance or technovigilance evidence from the reference market, translated into Spanish under RIS Art. 153

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

MexicoUS FDA · Health Canada · Japan MHLW / PMDA · IMDRF member authorities · MDSAP

Prior approval / evidence record

Class II

Id

class-ii

Class Name

Class II

Risk Level

medium

Pathway

Registration or Equivalency

Official Timeline
Min

35

Max

35

Unit

days

Verification Status

official-verified

Official Source
Title

RIS Art. 179 — statutory resolution periods by class (COFEPRIS)

Url

https://salud.gob.mx/unidades/cdi/nom/compi/ris.html

Accessed Date

2026-08-25

Realistic Timeline
Min

15

Max

31

Unit

months

With Prior Approval
Min

8

Max

16

Unit

months

Prior Approval Benefits
  • FDA 510(k)
  • Health Canada
  • Japan PMDA
  • IMDRF Committee Members
  • MDSAP
Notes
  • RIS Art. 179: Clase II resolved within 35 calendar days (15 days with a favourable Tercero Autorizado dictamen)
  • ARR equivalence route (COFEPRIS-04-050, Lineamientos DOF 18-07-2025): maximum 30 working days
  • Equivalency route much faster if FDA approved
Clinical Trial Required

No

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

MexicoUS FDA · Health Canada · Japan MHLW / PMDA · IMDRF member authorities · MDSAP

Prior approval / evidence record

Class III

Id

class-iii

Class Name

Class III

Risk Level

highest

Pathway

Registration or Equivalency

Official Timeline
Min

60

Max

60

Unit

days

Verification Status

official-verified

Official Source
Title

RIS Art. 179 — statutory resolution periods by class (COFEPRIS)

Url

https://salud.gob.mx/unidades/cdi/nom/compi/ris.html

Accessed Date

2026-08-25

Realistic Timeline
Min

15

Max

31

Unit

months

With Prior Approval
Min

8

Max

16

Unit

months

Prior Approval Benefits
  • FDA 510(k)/PMA
  • Health Canada
  • Japan PMDA
  • IMDRF Committee Members
  • MDSAP
Notes
  • RIS Art. 179: Clase III resolved within 60 calendar days (15 days with a favourable Tercero Autorizado dictamen)
  • ARR equivalence route (COFEPRIS-04-050): maximum 30 working days
  • Equivalency pathway best option with FDA
Clinical Trial Required

Yes

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

ParaguayBrazil ANVISA · US FDA · Health Canada · Austria · Belgium · Denmark · Finland · France · Germany · Hungary · Ireland · Italy · Netherlands · New Zealand · Norway · Spain · Sweden · Japan MHLW / PMDA · UK MHRA · Swissmedic · Australia TGA · WHO

Prior approval / evidence record

IVD Annex I reference-country list drives the 30/45/120-business-day clocks

reliance.ivd-anexo-i-reference-country-list
Fact-level verified
Statement

For IVDs, DINAVISA decides within 30 business days for products manufactured nationally or in a country of Annex I, within 45 business days for products manufactured outside Annex I but registered and commercialised in an Annex I country (which must additionally file the foreign registration certificate and free-sale certificate), and within 120 business days for other imports. Annex I names high-surveillance and adequate-surveillance authorities and the full MERCOSUR members; the United States and Japan are on it and Korea is not.

Source Approval

Sanitary registration and free-sale certificate in force in an Annex I country — high-surveillance authorities (Germany, Austria, Belgium, Canada, Denmark, Spain, United States, France, Israel, Italy, Japan, Netherlands, United Kingdom, Sweden, Switzerland) or adequate-surveillance authorities (Australia, Chile, Cuba, Finland, Hungary, Ireland, Luxembourg, Mexico, Norway, New Zealand); Annex I also lists full MERCOSUR members (Argentina, Brazil, Paraguay, Uruguay) and PAHO/WHO reference authorities

Edge Type

Abridged Or Recognition Route

Market Access Strength

facilitated

Regulatory Layer

Premarket Review

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • The Annex I list derives from Ley N° 3283/2007 Art. 11 (high and adequate sanitary surveillance).
  • A product made outside Annex I is admitted on a 45-day clock only if it is registered and commercialised in an Annex I country.
  • Korea (MFDS) does not appear in Annex I, so a Korean-only IVD authorisation does not by itself reach the 30/45-day clocks.
  • A Paraguayan sanitary registration is still required in every case.

Source language: Spanish. Translation of the quoted Annex I heading and entries: 'Countries with High and Adequate Sanitary Surveillance Authorities (Law 3283/07 Article 11)' / 'Countries with high sanitary surveillance regulatory authorities: Germany, Austria, Belgium, Canada, Denmark, Spain, United States, France, Israel, Italy, Japan, Netherlands, United Kingdom, Sweden and Switzerland.' / 'Full MERCOSUR members: Argentina, Brazil, Paraguay and Uruguay.' The excerpt is taken from the resolution's own Annex I; Art. 6 supplies the 30- and 45-business-day clocks.

ParaguayWHO · IMDRF member authorities

Prior approval / evidence record

PAHO/WHO reference authority or IMDRF Management Committee member authority

Authority

PAHO/WHO reference authority or IMDRF Management Committee member authority

Accepted

Yes

Benefit

Operative for class II, III and IV IVDs, which enter the Proceso Simplificado de Registro Sanitario under Resolución DINAVISA N° 44/2024 with a 15-business-day validation and approval by positive silence.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

ParaguayBrazil ANVISA · EU conformity assessment · US FDA · Health Canada · Singapore HSA · IMDRF member authorities · Portugal · Spain · South Korea MFDS · Japan MHLW / PMDA · UK MHRA · NMPA · Taiwan TFDA · Australia TGA · WHO

Prior approval / evidence record

IVD simplified registration (PSR) for products authorised by PAHO/WHO, IMDRF or bilateral-partner authorities

reliance.ivd-psr-reference-authorities
Fact-level verified
Statement

Class II, III and IV in-vitro diagnostic products already authorised and commercialised in countries regulated by PAHO/WHO reference regulatory authorities, by authorities of IMDRF Management Committee member countries, or by authorities with bilateral agreements with DINAVISA enter the Proceso Simplificado de Registro Sanitario (PSR). DINAVISA has 15 business days to validate and decide, and approval follows by positive silence if no report is issued.

Source Approval

PAHO/WHO reference regulatory authorities; authorities of IMDRF Management Committee member countries (the IMDRF committee includes US FDA, EU, Japan PMDA/MHLW, Health Canada, TGA, ANVISA, China NMPA, Korea MFDS, Singapore HSA and UK MHRA); authorities with bilateral agreements with DINAVISA

Edge Type

Abridged Or Recognition Route

Market Access Strength

facilitated

Regulatory Layer

Premarket Review

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • Applies to class II, III and IV IVDs (Res. 44/2024 Art. 7: 'Clases II, III y IV'); class I IVDs are registered automatically under Res. 266/2022 Art. 14.
  • The IVD must actually be commercialised in one of those countries and the foreign registration must correspond specifically to the same product being registered.
  • 15 business days to validate; approval by positive silence.
  • Objections may be answered only once (Art. 3), with 30 business days to rectify.
  • Not applicable to the cases in Arts. 13 and 16 of Res. DINAVISA N° 266/2022 (Art. 11).

Effective from 2024-01-30

Source language: Spanish. Translation of the operative part of Art. 2: 'Applications for sanitary registration of In Vitro Diagnostic Products ... that are authorised and commercialised in countries regulated by: PAHO/WHO Reference Regulatory Authorities; Regulatory Authorities of member countries of the Committee of the International Medical Device Regulators Forum - IMDRF; Regulatory Authorities with which bilateral agreements with DINAVISA exist, shall be subject to the Simplified Sanitary Registration Process (PSR).' and 'DINAVISA shall have a term of 15 (fifteen) business days to validate the required documentation and decide thereon. Once the term has elapsed with no report from DINAVISA, the application shall be approved.' Article numbering confirmed by reading the page image of the official PDF.

ParaguayWHO · IMDRF member authorities

Prior approval / evidence record

Proceso simplificado de Registro Sanitario (PSR) para productos para diagnóstico de uso in vitro

Name

Proceso simplificado de Registro Sanitario (PSR) para productos para diagnóstico de uso in vitro

Description

Class II, III and IV IVDs (Res. 44/2024 Art. 7) already authorised and commercialised by a recognised reference authority are validated in 15 business days with approval by positive silence, instead of the 30, 45 or 120 business days of the ordinary IVD route.

Timeline Reduction

From 30-120 business days down to 15 business days

Eligibility
  • Product classified as class II, III or IV under Resolución DINAVISA N° 266/2022 Art. 9
  • Current authorisation and commercialisation in a country regulated by a PAHO/WHO reference regulatory authority, by an IMDRF Management Committee member authority, or by an authority with a bilateral agreement with DINAVISA
  • The foreign registration must correspond specifically to the same product being registered in Paraguay

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

PeruUS FDA · EU conformity assessment · Brazil ANVISA

Prior approval / evidence record

Class III

Id

class-iii

Class Name

Class III

Risk Level

high

Pathway

Registration

Official Timeline
Min

66

Max

66

Unit

working-days

Verification Status

official-verified

Official Source
Title

DIGEMID TUPA (D.S. 011-2026-SA) — device procedure attention periods

Url

https://cdn.www.gob.pe/uploads/document/file/10349703/8409411-tupa-parte-2.pdf

Accessed Date

2026-08-25

Realistic Timeline
Min

6

Max

12

Unit

months

With Prior Approval
Min

4

Max

7

Unit

months

Prior Approval Benefits
  • FDA 510(k)/PMA
  • EU CE Mark
  • ANVISA
Notes
  • TUPA (D.S. 011-2026-SA): Clase III within 66 business days; statutory parallel cap 90 calendar days (Art. 136)
  • Technical file review required
Clinical Trial Required

No

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

PeruUS FDA · EU conformity assessment · Brazil ANVISA

Prior approval / evidence record

Class II

Id

class-ii

Class Name

Class II

Risk Level

medium

Pathway

Registration

Official Timeline
Min

44

Max

44

Unit

working-days

Verification Status

official-verified

Official Source
Title

DIGEMID TUPA (D.S. 011-2026-SA) — device procedure attention periods

Url

https://cdn.www.gob.pe/uploads/document/file/10349703/8409411-tupa-parte-2.pdf

Accessed Date

2026-08-25

Realistic Timeline
Min

4

Max

8

Unit

months

With Prior Approval
Min

3

Max

5

Unit

months

Prior Approval Benefits
  • FDA 510(k)
  • EU CE Mark
  • ANVISA
Notes
  • TUPA (D.S. 011-2026-SA): Clase II within 44 business days; statutory parallel cap 60 calendar days (Art. 136)
  • CAN harmonization applies
Clinical Trial Required

No

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

PeruBrazil ANVISA

Prior approval / evidence record

ANVISA (Brazil)

Authority

ANVISA (Brazil)

Accepted

No

Benefit

Brazil is neither a high-surveillance country under art. 9 nor a member of the Andean Community, so neither the documentary route nor CAN harmonisation applies to a Brazilian registration.

Timeline Savings

None

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

UgandaWHO · IMDRF member authorities · ISO

Prior approval / evidence record

WHO Prequalification, or quality-system certification from a certification body accredited by a regulatory authority in an IMDRF founding-member country, or any other international organisation recognised by NDA

Authority

WHO Prequalification, or quality-system certification from a certification body accredited by a regulatory authority in an IMDRF founding-member country, or any other international organisation recognised by NDA

Accepted

Yes

Benefit

Track 2: accepted as a documentary substitution for an IMDRF-country licence under DAR/GDL/028 §4.12.2 — the foreign element that unlocks the route is the quality-system certification and its accreditation rather than a product approval, and no shortened period is published for it.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

UgandaAustralia TGA · Health Canada · EU conformity assessment · Japan MHLW / PMDA · US FDA · IMDRF member authorities

Prior approval / evidence record

Licence or approval from an IMDRF founding-member country — Australia, Canada, the European Union, Japan, the United States

Authority

Licence or approval from an IMDRF founding-member country — Australia, Canada, the European Union, Japan, the United States

Accepted

Yes

Benefit

Track 1: an abridged evaluation in which the foreign approval carries the technical assessment, with a much smaller submission (attestation, abbreviated product and manufacturer details, notarized copy of the licence, Certificate of Analysis to an accepted quality-system standard, evidence of repeat sales and product samples where practicable). It is an expedited review with shortened registration timelines, but NDA publishes no number for the shortening and the final decision remains NDA's.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

ZambiaIMDRF member authorities · WHO · US FDA · EU conformity assessment

Prior approval / evidence record

WHO Prequalification; US FDA approval; EU CE marking; approval in any IMDRF member state

Authority

WHO Prequalification; US FDA approval; EU CE marking; approval in any IMDRF member state

Accepted

No

Benefit

Disclosure only. The Annex I application form requires the applicant to state whether the device is WHO prequalified, US FDA approved, CE marked or approved in any IMDRF member state and to attach valid documentation, but neither the non-IVD nor the IVD guideline attaches any procedural consequence — no shortened clock, no abridged dossier and no substitute for ZAMRA's own evaluation.

Maintained reference · planning ranges remain estimates · reviewed 2026-09-16

Prior approvals and evidence for Brazil (12 records)

BrazilEU conformity assessment

Prior approval / evidence record

EU CE Mark

Authority

EU CE Mark

Accepted

No

Benefit

Not an AREE under IN 290/2024 Art. 6

Timeline Savings

None

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilJapan MHLW / PMDA

Prior approval / evidence record

Japan MHLW

Authority

Japan MHLW

Accepted

Yes

Benefit

Recognised AREE for IN 290/2024, evidenced by the Shonin pre-market approval

Timeline Savings

None published

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilHealth Canada

Prior approval / evidence record

Health Canada

Authority

Health Canada

Accepted

Yes

Benefit

Recognised AREE for IN 290/2024, evidenced by the Medical Device Licence

Timeline Savings

None published

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilUS FDA · MDSAP

Prior approval / evidence record

Class IV

Id

class-iv

Class Name

Class IV

Risk Level

highest

Pathway

Registration

Official Timeline
Min

250

Max

320

Unit

days

Verification Status

official-verified

Official Source
Title

ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

Url

https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

Accessed Date

2026-08-25

Realistic Timeline
Min

1

Max

11

Unit

months

With Prior Approval
Min

10

Max

14

Unit

months

Prior Approval Benefits
  • FDA 510(k)/PMA (via IN 290/2024)
  • MDSAP for B-GMP
Notes
  • RDC 743/2022 Anexo: equipment registration 250 days, materials Risk III registration 320 days (no tacit approval for Risk III materials), IVD 365 days
  • Lei 6.360/1976 Art. 12 §3º separately binds ANVISA to 90 days for health-product petitions — RDC 743 subject-specific clocks govern in practice
  • Clinical evidence mandatory
  • 10 year validity
Clinical Trial Required

Yes

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilNMPA

Regulatory reference

China NMPA approval: not reference

reliance.china-nmpa-not-reference
Pending verification
Statement

ANVISA's optimized (reliance) review for Class III/IV device registration under RDC 741/2022 is available only for devices previously authorized by an AREE listed exhaustively in IN 290/2024 Art. 6: TGA (ARTG), Health Canada (Medical Device Licence), US FDA (510(k)/PMA/De Novo) and Japan MHLW (Shonin). China's NMPA is not listed, so an NMPA registration certificate gives no access to the optimized procedure and the ordinary route (RDC 751/2022 / RDC 830/2023) applies.

Source Jurisdiction Id

china

Source Authority Id

nmpa

Source Approval

China NMPA medical device registration certificate (Class II/III) or Class I filing record

Target Jurisdiction Id

brazil

China Classes In Scope

NMPA Class II/III certificates and Class I filings; target: ANVISA Class III/IV registration (optimized procedure)

Edge Type

No Reliance Route

Market Access Strength

none

Regulatory Layer

Product Marketing

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • Art. 7 I: device must be authorized by at least one AREE listed in Art. 6
  • Art. 7 II: AREE document must refer to an essentially identical device
  • Art. 13: ANVISA retains independent decision
  • Independent verification is incomplete. Treat this record as a research lead, not a confirmed benefit or exclusion; see the 2026-09-15 independent review.

Effective from 2024-06-03

Source passage: Art. 6º Para fins de adoção do procedimento otimizado de análise são consideradas as seguintes AREE e respectivas comprovações de registro ou autorização: I - Austrália: Australia Therapeutic Goods Administration (TGA) - Australian Register of Therapeutic Goods (ARTG); II - Canadá: Health Canada (HC) - Medical Device Licence; III - Estados Unidos da América (EUA): US Food and Drug Administration (US FDA) - 510(k) Clearance, Premarket Approval (PMA) ou 513(f)(2) "De Novo"; e IV - Japão: Japan Ministry of Health, Labour and Welfare (MHLW) - Pre-market approval (Shonin).

BrazilUS FDA · MDSAP

Prior approval / evidence record

Class III

Id

class-iii

Class Name

Class III

Risk Level

high

Pathway

Registration

Official Timeline
Min

250

Max

320

Unit

days

Verification Status

official-verified

Official Source
Title

ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

Url

https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

Accessed Date

2026-08-25

Realistic Timeline
Min

1

Max

11

Unit

months

With Prior Approval
Min

8

Max

12

Unit

months

Prior Approval Benefits
  • FDA 510(k)/PMA (via IN 290/2024)
  • MDSAP for B-GMP
Notes
  • RDC 743/2022 Anexo: equipment registration 250 days, materials Risk III registration 320 days (no tacit approval for Risk III materials), IVD 365 days
  • Lei 6.360/1976 Art. 12 §3º separately binds ANVISA to 90 days for health-product petitions — RDC 743 subject-specific clocks govern in practice
  • B-GMP certificate mandatory
  • 10 year validity
Clinical Trial Required

No

Local Testing Required

No

Gmp Required

Yes

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilMDSAP

Prior approval / evidence record

MDSAP B-GMP validity extension (RDC 850/2024)

Name

MDSAP B-GMP validity extension (RDC 850/2024)

Description

RDC 497/2021 Art. 8 gives a Brazilian GMP certificate two years. RDC 850/2024 added a first paragraph doubling that to four years where the certificate was granted through MDSAP, conditional on the manufacturer staying in MDSAP for the whole certificate period.

Timeline Reduction

4 years of B-GMP validity instead of 2, so one renewal cycle removed

Eligibility
  • Manufacturer participates in MDSAP
  • Participation maintained throughout the validity of the certificate

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilNMPA

Prior approval / evidence record

NMPA-ANVISA cooperation MoU (2020): no recognition effect

reliance.china-nmpa-bilateral-programme
Pending verification
Statement

NMPA Commissioner Jiao Hong and ANVISA Director-President Antonio Barra Torres signed a Memorandum of Understanding on cooperation on 26 November 2020 covering information exchange in the regulation of drugs, medical devices and cosmetics. ANVISA's official cooperation page lists the 'Memorando de Entendimento entre Anvisa e NMPA' under China, and a separate BRICS regulators' MoU. Neither instrument creates recognition of NMPA registrations; they are information-exchange frameworks.

Source Jurisdiction Id

china

Source Authority Id

nmpa

Source Approval

China NMPA medical device registration certificate (Class II/III) or Class I filing record

Target Jurisdiction Id

brazil

China Classes In Scope

All device classes (framework MoU; no product-level effect)

Edge Type

Cooperation Mou

Market Access Strength

none

Regulatory Layer

Product Marketing

Local Application Required

Yes

Target Decision Retained

Yes

Conditions
  • Information exchange only; no reliance or mutual recognition of registrations
  • ANVISA also lists a BRICS (RU/IN/CN/ZA) regulators' MoU
  • Independent verification is incomplete. Treat this record as a research lead, not a confirmed benefit or exclusion; see the 2026-09-15 independent review.

Effective from 2020-11-26

Source passage: The National Medical Products Administration (NMPA) Commissioner Jiao Hong signed a memorandum of understanding (MoU) on cooperation with Antonio Barra Torres, head of the Brazilian health regulatory agency ... on Nov 26. ... have agreed to further strengthen information exchanges in regulation of drugs, medical devices and cosmetics under the framework of the MoU

BrazilMDSAP

Prior approval / evidence record

MDSAP

Authority

MDSAP

Accepted

Yes

Benefit

Audit reports substitute for the inspection report at B-GMP certification and extend the certificate to 4 years, but RDC 687/2022 Art. 14 keeps ANVISA free to inspect on site at any time, including during the certificate validity

Timeline Savings

Removes the wait for an ANVISA inspection slot

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilUS FDA

Prior approval / evidence record

FDA 510(k)/PMA/De Novo

Authority

FDA 510(k)/PMA/De Novo

Accepted

Yes

Benefit

Recognised AREE for IN 290/2024 optimized analysis of Class III and IV registrations

Timeline Savings

None published — Art. 10 preserves queue position

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilUS FDA · Australia TGA · Health Canada · Japan MHLW / PMDA · Brazil ANVISA

Prior approval / evidence record

Optimized analysis (procedimento otimizado, IN 290/2024)

Name

Optimized analysis (procedimento otimizado, IN 290/2024)

Description

ANVISA uses the analysis already performed by a recognised equivalent foreign regulator as the sole or complementary reference for the registration decision. It shortens how much ANVISA has to re-review, not where the petition sits in the queue: Art. 10 states expressly that adopting the optimized procedure does not change the chronological order of petitions, and ANVISA publishes no reduced deadline for it.

Timeline Reduction

No published reduction — the RDC 743/2022 deadlines still apply and Art. 10 preserves queue position

Eligibility
  • Class III and IV primary registration petitions only, medical devices and IVDs (Art. 2)
  • Prior authorisation by one of the four recognised AREE: TGA via the ARTG, Health Canada via a Medical Device Licence, US FDA via 510(k), PMA or De Novo, or Japan MHLW via Shonin (Art. 6)
  • The device must be essentially identical to the one the AREE authorised, down to composition, indications, manufacturer and manufacturing process (Art. 5 II)
  • Excluded if the AREE itself granted the authorisation through an abbreviated route similar to ANVISA optimized analysis (Art. 4)
  • Filed as a secondary aditamento petition; omit it and the registration is analysed by the ordinary route (Art. 11)
  • ANVISA keeps the right to revert to ordinary analysis with reasons (Art. 9) and to decide differently from the AREE (Art. 13)

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

BrazilAustralia TGA

Prior approval / evidence record

TGA (Australia)

Authority

TGA (Australia)

Accepted

Yes

Benefit

Recognised AREE for IN 290/2024, evidenced by the ARTG entry

Timeline Savings

None published

Maintained reference · planning ranges remain estimates · reviewed 2026-08-30

Review clocks

What review, validation, and applicant stop-clock rules apply?

Compare countries

Approval clocks depend on a complete instruction

changes.change-clock-completeness
Fact-level verified

Under Decree 10178 Arts. 10–15, the approval period starts when all necessary instruction elements are submitted; the authority must state the deadline. A documentary-complement request can suspend the clock, with the stated new-fact exception. These provisions do not create a universal 60-day or 90-day device alteration period.

Listed alteration decision periods are not all implementation dates

changes.change-specific-decision-table
Fact-level verified

RDC 743’s Annex lists 30 days for the enumerated immediate device/IVD alteration subjects and 150 days for approval-required subjects; the latter rows exclude tacit approval. These are printed as days, not expressly working days. MD Art. 22 as replaced by RDC 777, and IVD RDC 830 Art. 22, provide publication independently of documentary review without printing the old 30-day publication phrase. Do not treat the table as a guaranteed pre-implementation wait or as approval for any combined transfer.

Conditions
  • The Annex retains historical RDC 340 cross-references. The actual listed subject, full instruction and express authority deadline govern.

UDI, listing & traceability

Which UDI, device listing, database, and traceability duties apply?

Compare countries

Commercial-name UDI rules do not identify an internal REF

changes.udi-change-boundary
Fact-level verified

RDC 591 Annex II2.9 as amended by RDC 884 requires a new UDI-DI where a change could create identification ambiguity, and expressly for trade/commercial-model name changes. Under2.12 a label change solely to add UDI is not itself a regularization-change petition. A customer’s internal REF is not automatically a commercial model or UDI-DI; establish what registered and issued identifiers actually change.

Conditions
  • Apply the class/product implementation stage and current SIUD suspension list; operation of SIUD is not a universal mandatory reporting date.

Product holder transfer precedes SIUD transfer

changes.udi-transfer-order
Fact-level verified

IN 426 Art. 8 requires completion of the formal RDC 903 holder transfer before SIUD data transfer; successor data are transmitted for the new registration numbers within 30 days after the individual transfer/cancellation resolutions take effect. Art. 7§3 separately gives30 calendar days from publication for replacement where the change requires a new UDI-DI. These data deadlines are not agency variation-review periods.

Conditions
  • Actual product/class reporting applicability and any published product-specific suspension must be checked.

Related structured datasets

Classification systems · 1 record
Open Risk classes I through IV for general devices and IVDs. →
Id

brazil:medical-device

Jurisdiction Id

brazil

Domains
  • medical-device
  • ivd
Name

Risk classes I through IV for general devices and IVDs.

Classes
  • Id

    i

    Label

    Class I

    Normalized Risk Level

    low

  • Id

    ii

    Label

    Class II

    Normalized Risk Level

    medium

  • Id

    iii

    Label

    Class III

    Normalized Risk Level

    high

  • Id

    iv

    Label

    Class IV

    Normalized Risk Level

    highest

Regulator

ANVISA

Official Domains
  • gov.br
  • anvisa.gov.br
Source Status

official-source-verified

Source Title

ANVISA RDC 751/2022 English translation

Source Url

https://www.gov.br/anvisa/pt-br/assuntos/produtosparasaude/temas-em-destaque/arquivos/2024/rdc-751-2022-en.pdf

Verified On

2026-08-13

Source Supports
  • class-axis
  • classification-rules
  • ivd-class-axis
  • ivd-classification-rules
Notes
  • Devices classify via 22 rules in Anexo I of RDC 751/2022 (IMDRF/GHTF-derived); IVDs classify into classes I-IV via 8 rules in Anexo I of RDC 830/2023 (Art. 5º). Classes I/II route to notification and III/IV to registration (Arts. 6º-7º RDC 751/2022). Re-confirmed 2026-08-25 against the ANVISA legislative text (anvisalegis.datalegis.net).
Registration pathways, prior approvals and planning · 1 record

These country-level records can cover multiple product types. Check each item's scope and conditions before applying a fee, pathway or licence to an IVD.

Open Brazil registration →
Country

Brazil

Jurisdiction Id

brazil

Country Code

BR

Flag

🇧🇷

Regulator

Agência Nacional de Vigilância Sanitária

Regulator Abbrev

ANVISA

Region

americas

Tier

1

Risk Classification

4-class (I, II, III, IV)

Classes
  • Id

    class-i

    Class Name

    Class I

    Risk Level

    low

    Pathway

    Notification

    Official Timeline
    Min

    30

    Max

    30

    Unit

    days

    Verification Status

    official-verified

    Official Source
    Title

    ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

    Accessed Date

    2026-08-25

    Realistic Timeline
    Min

    1

    Max

    1.5

    Unit

    months

    Notes
    • Notificação decided within 30 days (RDC 743/2022 Anexo)
    • No ANVISA review of technical merit
    • Unlimited validity
    Clinical Trial Required

    No

    Local Testing Required

    No

    Gmp Required

    No

  • Id

    class-ii

    Class Name

    Class II

    Risk Level

    medium

    Pathway

    Notification

    Official Timeline
    Min

    30

    Max

    30

    Unit

    days

    Verification Status

    official-verified

    Official Source
    Title

    ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

    Accessed Date

    2026-08-25

    Realistic Timeline
    Min

    1

    Max

    1.5

    Unit

    months

    Notes
    • Notificação decided within 30 days (RDC 743/2022 Anexo)
    • Unlimited validity
    • INMETRO certification adds 3-12 months if required
    Clinical Trial Required

    No

    Local Testing Required

    No

    Gmp Required

    No

  • Id

    class-iii

    Class Name

    Class III

    Risk Level

    high

    Pathway

    Registration

    Official Timeline
    Min

    250

    Max

    320

    Unit

    days

    Verification Status

    official-verified

    Official Source
    Title

    ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

    Accessed Date

    2026-08-25

    Realistic Timeline
    Min

    1

    Max

    11

    Unit

    months

    With Prior Approval
    Min

    8

    Max

    12

    Unit

    months

    Prior Approval Benefits
    • FDA 510(k)/PMA (via IN 290/2024)
    • MDSAP for B-GMP
    Notes
    • RDC 743/2022 Anexo: equipment registration 250 days, materials Risk III registration 320 days (no tacit approval for Risk III materials), IVD 365 days
    • Lei 6.360/1976 Art. 12 §3º separately binds ANVISA to 90 days for health-product petitions — RDC 743 subject-specific clocks govern in practice
    • B-GMP certificate mandatory
    • 10 year validity
    Clinical Trial Required

    No

    Local Testing Required

    No

    Gmp Required

    Yes

  • Id

    class-iv

    Class Name

    Class IV

    Risk Level

    highest

    Pathway

    Registration

    Official Timeline
    Min

    250

    Max

    320

    Unit

    days

    Verification Status

    official-verified

    Official Source
    Title

    ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

    Accessed Date

    2026-08-25

    Realistic Timeline
    Min

    1

    Max

    11

    Unit

    months

    With Prior Approval
    Min

    10

    Max

    14

    Unit

    months

    Prior Approval Benefits
    • FDA 510(k)/PMA (via IN 290/2024)
    • MDSAP for B-GMP
    Notes
    • RDC 743/2022 Anexo: equipment registration 250 days, materials Risk III registration 320 days (no tacit approval for Risk III materials), IVD 365 days
    • Lei 6.360/1976 Art. 12 §3º separately binds ANVISA to 90 days for health-product petitions — RDC 743 subject-specific clocks govern in practice
    • Clinical evidence mandatory
    • 10 year validity
    Clinical Trial Required

    Yes

    Local Testing Required

    No

    Gmp Required

    Yes

Expedited Pathways
  • Name

    Optimized analysis (procedimento otimizado, IN 290/2024)

    Description

    ANVISA uses the analysis already performed by a recognised equivalent foreign regulator as the sole or complementary reference for the registration decision. It shortens how much ANVISA has to re-review, not where the petition sits in the queue: Art. 10 states expressly that adopting the optimized procedure does not change the chronological order of petitions, and ANVISA publishes no reduced deadline for it.

    Timeline Reduction

    No published reduction — the RDC 743/2022 deadlines still apply and Art. 10 preserves queue position

    Eligibility
    • Class III and IV primary registration petitions only, medical devices and IVDs (Art. 2)
    • Prior authorisation by one of the four recognised AREE: TGA via the ARTG, Health Canada via a Medical Device Licence, US FDA via 510(k), PMA or De Novo, or Japan MHLW via Shonin (Art. 6)
    • The device must be essentially identical to the one the AREE authorised, down to composition, indications, manufacturer and manufacturing process (Art. 5 II)
    • Excluded if the AREE itself granted the authorisation through an abbreviated route similar to ANVISA optimized analysis (Art. 4)
    • Filed as a secondary aditamento petition; omit it and the registration is analysed by the ordinary route (Art. 11)
    • ANVISA keeps the right to revert to ordinary analysis with reasons (Art. 9) and to decide differently from the AREE (Art. 13)
  • Name

    MDSAP B-GMP validity extension (RDC 850/2024)

    Description

    RDC 497/2021 Art. 8 gives a Brazilian GMP certificate two years. RDC 850/2024 added a first paragraph doubling that to four years where the certificate was granted through MDSAP, conditional on the manufacturer staying in MDSAP for the whole certificate period.

    Timeline Reduction

    4 years of B-GMP validity instead of 2, so one renewal cycle removed

    Eligibility
    • Manufacturer participates in MDSAP
    • Participation maintained throughout the validity of the certificate
Prior Approvals
  • Authority

    FDA 510(k)/PMA/De Novo

    Accepted

    Yes

    Benefit

    Recognised AREE for IN 290/2024 optimized analysis of Class III and IV registrations

    Timeline Savings

    None published — Art. 10 preserves queue position

  • Authority

    EU CE Mark

    Accepted

    No

    Benefit

    Not an AREE under IN 290/2024 Art. 6

    Timeline Savings

    None

  • Authority

    MDSAP

    Accepted

    Yes

    Benefit

    Audit reports substitute for the inspection report at B-GMP certification and extend the certificate to 4 years, but RDC 687/2022 Art. 14 keeps ANVISA free to inspect on site at any time, including during the certificate validity

    Timeline Savings

    Removes the wait for an ANVISA inspection slot

  • Authority

    TGA (Australia)

    Accepted

    Yes

    Benefit

    Recognised AREE for IN 290/2024, evidenced by the ARTG entry

    Timeline Savings

    None published

  • Authority

    Health Canada

    Accepted

    Yes

    Benefit

    Recognised AREE for IN 290/2024, evidenced by the Medical Device Licence

    Timeline Savings

    None published

  • Authority

    Japan MHLW

    Accepted

    Yes

    Benefit

    Recognised AREE for IN 290/2024, evidenced by the Shonin pre-market approval

    Timeline Savings

    None published

Key Requirements
  • Brazil Registration Holder (BRH) - mandatory for foreign manufacturers
  • B-GMP certificate (Class III & IV)
  • Portuguese labeling and IFU
  • Clinical evidence (Class III & IV)
  • UDI (phased: Class IV Jul 2025, Class III Jan 2026)
  • Post-registration clocks: revalidação decided within 180 days (silence = approval); alteração (changes) within 150 days
Local Rep Required

Yes

Local Rep Name

Brazil Registration Holder (BRH)

Mdsap Accepted

Yes

Mdsap Benefit

MDSAP audit reports stand in for the inspection report when ANVISA grants or renews the B-GMP certificate, and RDC 850/2024 extends that certificate to 4 years for as long as the manufacturer stays in the programme. It is not an inspection waiver: RDC 687/2022 Art. 14 lets ANVISA inspect on site at any time, and refusing an inspection cancels the certificate.

Registration Validity

Unlimited (Class I-II), 10 years (Class III-IV)

Verification Status

official-verified

Official Sources
  • Title

    ANVISA RDC 743/2022 — analysis deadlines per subject and act (Anexo)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000743&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_modulo=310&cod_menu=9434

    Accessed Date

    2026-08-25

  • Title

    ANVISA IN 290/2024 — optimized analysis of Class III and IV device registration petitions using an equivalent foreign regulator (AREE)

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=INM&numeroAto=00000290&seqAto=000&valorAno=2024&orgao=DC/ANVISA/MS&cod_menu=1696&cod_modulo=134

    Effective Date

    2024-06-03

    Accessed Date

    2026-08-30

  • Title

    ANVISA RDC 687/2022 — criteria for granting and renewing the Brazilian GMP certificate for medical devices

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000687&seqAto=000&valorAno=2022&orgao=RDC/DC/ANVISA/MS&cod_menu=1696&cod_modulo=134

    Effective Date

    2022-06-01

    Accessed Date

    2026-08-30

  • Title

    ANVISA RDC 850/2024 — amends RDC 497/2021 Art. 8 to give MDSAP-based device GMP certificates four years of validity

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&tipo=RDC&numeroAto=00000850&seqAto=000&valorAno=2024&orgao=RDC/DC/ANVISA/MS&cod_menu=1696&cod_modulo=134

    Effective Date

    2024-04-01

    Accessed Date

    2026-08-30

Reviewed On

2026-08-30

Last Updated

2026-08-30

Process
Template Id

brazil

Status

planning-template

Usage Rule

Maintained planning steps and estimates, not verified regulator deadlines.

Steps
  • Step

    1

    Title

    Device Classification

    Description

    Classify device under ANVISA RDC 751/2022 (Class I, II, III, or IV).

    Duration

    2-4 weeks

    Icon

    🏷️

  • Step

    2

    Title

    Appoint BRH

    Description

    Foreign manufacturers must appoint a Brazil Registration Holder (BRH) for registration.

    Duration

    4-8 weeks

    Icon

    🏛️

  • Step

    3

    Title

    GMP Certificate

    Description

    Obtain ANVISA B-GMP certificate or MDSAP certificate covering Brazil. Facility audit required.

    Duration

    6-12 months

    Icon

    🏭

  • Step

    4

    Title

    Technical Documentation

    Description

    Prepare ANVISA-compliant technical dossier. Portuguese translation required.

    Duration

    2-4 months

    Icon

    📋

  • Step

    5

    Title

    ANVISA Submission

    Description

    BRH submits registration application to ANVISA via electronic system.

    Duration

    1-2 weeks

    Icon

    📤

  • Step

    6

    Title

    ANVISA Review

    Description

    ANVISA conducts technical review. IN 290/2024 offers faster pathway with FDA/EU/TGA approval.

    Duration

    6-18 months

    Icon

    ⚙️

  • Step

    7

    Title

    Registration

    Description

    ANVISA issues registration. Valid 10 years (or 5 years without MDSAP).

    Duration

    2-4 weeks

    Icon

    ✅

Government fee schedules · 1 record

These country-level records can cover multiple product types. Check each item's scope and conditions before applying a fee, pathway or licence to an IVD.

Open Brazil fees →
Jurisdiction Id

brazil

Country

Brazil

Country Code

BR

Authority

ANVISA

Low Risk Local
Min

175.72

Max

3514.32

Currency

BRL

Per Product

Yes

High Risk Local
Min

780.96

Max

49641.2

Currency

BRL

Per Product

Yes

Details
  • Id

    notification-class-i-ii

    Item

    Class I/II notification (fato gerador 752)

    Currency

    BRL

    Amount Local

    3514.32

    Amount Local Min

    175.72

    Amount Local Max

    3514.32

    Amount Local Formatted

    BRL 175.72–3,514.32

    Frequency

    Per notification

    Notes

    Exact payable amount depends on the ANVISA-recognized company-size group.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    registration-medium-small-device

    Item

    Class III/IV registration — medium/small device (731)

    Currency

    BRL

    Amount Local

    15619.2

    Amount Local Min

    780.96

    Amount Local Max

    15619.2

    Amount Local Formatted

    BRL 780.96–15,619.20

    Frequency

    Per registration

    Notes

    Single device; range is microenterprise through Group I large enterprise.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    registration-medium-small-family

    Item

    Class III/IV registration — medium/small family (733)

    Currency

    BRL

    Amount Local

    21274.8

    Amount Local Min

    1063.74

    Amount Local Max

    21274.8

    Amount Local Formatted

    BRL 1,063.74–21,274.80

    Frequency

    Per family registration

    Notes

    Range is microenterprise through Group I large enterprise.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    registration-large-device

    Item

    Class III/IV registration — large equipment (730)

    Currency

    BRL

    Amount Local

    39048

    Amount Local Min

    1952.4

    Amount Local Max

    39048

    Amount Local Formatted

    BRL 1,952.40–39,048.00

    Frequency

    Per registration

    Notes

    Large diagnostic or therapeutic equipment; range depends on company size.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    registration-large-family

    Item

    Class III/IV registration — large-equipment family (732)

    Currency

    BRL

    Amount Local

    49641.2

    Amount Local Min

    2482.06

    Amount Local Max

    49641.2

    Amount Local Formatted

    BRL 2,482.06–49,641.20

    Frequency

    Per family registration

    Notes

    Range is microenterprise through Group I large enterprise.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    renewal-medium-small-device

    Item

    Registration renewal — medium/small device (735)

    Currency

    BRL

    Amount Local

    14057.28

    Amount Local Min

    702.86

    Amount Local Max

    14057.28

    Amount Local Formatted

    BRL 702.86–14,057.28

    Frequency

    Per renewal

    Notes

    The Annex already includes the renewal discount and company-size reductions.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    renewal-medium-small-family

    Item

    Registration renewal — medium/small family (736)

    Currency

    BRL

    Amount Local

    19147.32

    Amount Local Min

    957.37

    Amount Local Max

    19147.32

    Amount Local Formatted

    BRL 957.37–19,147.32

    Frequency

    Per family renewal

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    renewal-large-device

    Item

    Registration renewal — large equipment (734)

    Currency

    BRL

    Amount Local

    35143.2

    Amount Local Min

    1757.16

    Amount Local Max

    35143.2

    Amount Local Formatted

    BRL 1,757.16–35,143.20

    Frequency

    Per renewal

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    renewal-large-family

    Item

    Registration renewal — large-equipment family (737)

    Currency

    BRL

    Amount Local

    44677.08

    Amount Local Min

    2233.85

    Amount Local Max

    44677.08

    Amount Local Formatted

    BRL 2,233.85–44,677.08

    Frequency

    Per family renewal

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    post-registration-change

    Item

    Post-registration change or inclusion (738)

    Currency

    BRL

    Amount Local

    3514.32

    Amount Local Min

    175.72

    Amount Local Max

    3514.32

    Amount Local Formatted

    BRL 175.72–3,514.32

    Frequency

    Per petition

    Notes

    Labeling/instructions-only changes under fact generator 742 are exempt.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    cbpf-brazil-mercosur

    Item

    GMP certification — Brazil or Mercosur site (726)

    Currency

    BRL

    Amount Local

    26593.5

    Amount Local Min

    1329.68

    Amount Local Max

    26593.5

    Amount Local Formatted

    BRL 1,329.68–26,593.50

    Frequency

    Per site and production line

    Notes

    Company-size discounts apply.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

  • Id

    cbpf-other-country

    Item

    GMP certification — site outside Mercosur (727)

    Currency

    BRL

    Amount Local

    72804.9

    Amount Local Formatted

    BRL 72,804.90

    Frequency

    Per site and production line

    Notes

    RDC 857/2024 excludes non-Mercosur GMP certification from company-size discounts.

    Amount Status

    exact-current

    Verification Status

    official-verified

    Source Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Source Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Source Effective Date

    2024-06-03

    Verified On

    2026-08-25

Notes
  • RDC 857/2024 Annex I publishes six exact TFVS amounts for each applicable fact generator: Group I/II large, Group III/IV medium, small, and microenterprise.
  • The displayed range is the official microenterprise-to-Group-I range, not an estimate. Without accepted proof of size, ANVISA assigns Group I and charges the maximum.
  • Registration and GMP certification are separate charges; foreign-site GMP is manufacturer/site-level rather than per device.
  • Statutory basis: Lei 9.782/1999 Anexo II (MP 2.190-34/2001) items 7.1-7.7 — AFE fabricante R$ 10,000 / distribuidora-importadora R$ 8,000 / varejista R$ 5,000; CBPF and CBPD/A R$ 15,000/ano; registro grande porte R$ 20,000 per 5 years and outros R$ 8,000; família grande porte R$ 28,000 and outros R$ 12,000; alteração R$ 1,800; certificado de exportação exempt; statutory porte reductions of 15/30/60/90/95% by company size. ANVISA’s TFVS page states collection follows RDC 222/2006 (amended by RDC 76/2008) Anexo I, so the Anexo II figures are the statutory basis rather than necessarily the currently collected values. GRU must be paid before petitioning and is valid 30 days.
Last Updated

2026-08-25

Verification Status

official-verified

Official Sources
  • Title

    ANVISA RDC 857/2024, Annex I TFVS fee matrix

    Url

    https://anvisalegis.datalegis.net/action/ActionDatalegis.php?acao=abrirTextoAto&codTipo=&cod_menu=1696&cod_modulo=134&desItem=&desItemFim=&numeroAto=00000857&orgao=RDC%2FDC%2FANVISA%2FMS&pesquisa=true&seqAto=000&tipo=RDC&valorAno=2024

    Effective Date

    2024-06-03

    Accessed Date

    2026-08-25

Reviewed On

2026-08-25

Amount Status

exact-current

Range Available

Yes

Additional certifications and licences · 1 record

These country-level records can cover multiple product types. Check each item's scope and conditions before applying a fee, pathway or licence to an IVD.

Open Brazil certifications →
Slug

brazil

Market

Brazil

Confidence

high

Schemes
  • Id

    inmetro-sbac-conformity-certificate

    Name

    INMETRO/SBAC conformity certificate

    Category

    Medical Electrical Safety

    Status

    Mandatory If Feature

    Object

    Covered Electromedical Or Listed Product

    Note

    ANVISA Registro FAQ Q5 directs to INMETRO IN 116/2021 and RDC 549/2021 for compulsory certification of certain electromedical equipment (electrical safety).

    Source Urls
    • https://www.gov.br/inmetro/pt-br/acesso-a-informacao/perguntas-frequentes/avaliacao-da-conformidade/equipamentos-sob-regime-de-vigilancia-sanitaria/como-certifico-um-produtos-sob-vigilancia-sanitaria
    Source Binding

    candidate

  • Id

    anatel-certification-and-homologation

    Name

    ANATEL certification and homologation

    Category

    Radio Spectrum

    Status

    Mandatory If Feature

    Object

    Radio Or Telecommunications Product

    Source Urls
    • https://www.gov.br/anatel/pt-br/regulado/certificacao-de-produtos
    Source Binding

    candidate

  • Id

    inmetro-legal-metrology-type-approval-verification

    Name

    INMETRO legal-metrology type approval/verification

    Category

    Legal Metrology

    Status

    Mandatory If Feature

    Object

    Regulated Measuring Instrument

    Source Urls
    • https://www.gov.br/inmetro/pt-br/assuntos/vigilancia-de-mercado/fiscalizaveis/instrumentos-de-medicao
    Source Binding

    candidate

  • Id

    ansn-cnen-radiation-import-transfer-use-authorization

    Name

    ANSN/CNEN radiation import/transfer/use authorization

    Category

    Ionizing Radiation

    Status

    Mandatory If Feature

    Object

    Radiation Equipment Source And Use Site

    Source Urls
    • https://www.gov.br/ansn/pt-br/servicos/instalacoes-radioativas/requerimentos-e-tlc
    Source Binding

    candidate

  • Id

    anvisa-sbac-product-specific-conformity

    Name

    ANVISA/SBAC product-specific conformity

    Category

    Product Specific Conformity

    Status

    Mandatory If Feature

    Object

    Listed Product Category

    Note

    RDC 848/2024 Art. 1 §3: essential safety and performance requirements are verified by the sanitary authority at GMP inspection, registration/notification or surveillance; labelling may use ABNT NBR ISO 15223 symbols (RDC 830/2023 Art. 46 VI).

    Source Urls
    • https://www.gov.br/anvisa/en/regulation-of-products/medical-devices
    Source Binding

    candidate

Official Sources
  • Authority

    ANVISA

    Topic

    medical devices and compulsory conformity

    Url

    https://www.gov.br/anvisa/en/regulation-of-products/medical-devices

  • Authority

    INMETRO

    Topic

    health-surveillance equipment certification

    Url

    https://www.gov.br/inmetro/pt-br/acesso-a-informacao/perguntas-frequentes/avaliacao-da-conformidade/equipamentos-sob-regime-de-vigilancia-sanitaria/como-certifico-um-produtos-sob-vigilancia-sanitaria

  • Authority

    ANATEL

    Topic

    telecommunications product certification

    Url

    https://www.gov.br/anatel/pt-br/regulado/certificacao-de-produtos

  • Authority

    INMETRO

    Topic

    legal metrology instruments

    Url

    https://www.gov.br/inmetro/pt-br/assuntos/vigilancia-de-mercado/fiscalizaveis/instrumentos-de-medicao

  • Authority

    ANSN/CNEN

    Topic

    radiation installation and equipment requests

    Url

    https://www.gov.br/ansn/pt-br/servicos/instalacoes-radioativas/requerimentos-e-tlc

  • Authority

    ANVISA

    Topic

    product registration FAQ INMETRO IN 116/2021 and RDC 549/2021 checklist

    Url

    https://www.gov.br/anvisa/pt-br/setorregulado/regularizacao/produtos-para-saude/registro/registro-de-produtos

Keep researching this market
View the Brazil resource hub →
Compare regulatory data across all countries →
DJ Fang
Need to apply Brazil's requirements to a product?
Confirm the current ANVISA pathway, evidence, and local-role details for the actual device before filing.
Pricing